Early Real-World Outcomes with a Novel Hybrid Full Range of Vision Intraocular Lens.
Аннотация
Background and
Objectives
We aimed to describe early real-world visual, refractive, and safety outcomes following implantation of a novel hybrid full range of vision intraocular lens (IOL) in patients undergoing cataract surgery. Materials and
Methods
This prospective, single-center, non-randomized clinical study included 50 patients (100 eyes) undergoing bilateral sequential cataract surgery with implantation of the Max Vision™ IOL. Uncorrected and corrected distance visual acuity (UDVA, CDVA) and uncorrected near visual acuity (UNVA) at 32 cm and 40 cm were assessed using logarithmic charts. Spherical equivalent (SE) refraction, intraocular pressure (IOP), and safety outcomes were recorded preoperatively and at postoperative day 1, week 1, and month 1. Preoperative and postoperative values were compared statistically.
Results
The mean age was 66.1 ± 7.9 years. At 1 month, mean UDVA improved from 0.58 ± 0.24 to 0.01 ± 0.03 logMAR, and mean CDVA from 0.18 ± 0.20 to -0.001 ± 0.01 logMAR (both p < 0.001). Mean UNVA improved from 0.64 ± 0.18 to 0.19 ± 0.10 logMAR at 32 cm and from 0.61 ± 0.15 to 0.13 ± 0.11 logMAR at 40 cm (both p < 0.001). Mean SE changed from 1.16 ± 1.7 D preoperatively to 0.04 ± 0.4 D at 1 month (p < 0.001). Mean IOP showed a transient increase on postoperative day 1 followed by a reduction at 1 month, without the need for additional hypotensive therapy. No eyes lost two or more lines of CDVA. One posterior capsular rupture occurred without postoperative sequelae.
Conclusions
At 1 month after cataract surgery, implantation of the Max Vision™ IOL was associated with improved distance and near visual acuity, early refractive accuracy, and no major short-term safety concerns, under routine clinical conditions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.