Compound muscle action potential amplitudes in newborn screen positive spinal muscular atrophy.

Samur Bahadir M, Salhotra Ekta Bery, Sadhu Sneha, Bheemisetty Niharika, He Zhulin, Verma Sumit

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the utility of compound muscle action potential (CMAP) amplitudes as biomarkers of disease severity in newborn screening (NBS)-positive infants with spinal muscular atrophy (SMA).

METHODS

We conducted a retrospective review of 21 infants identified through SMA NBS (11 with 2 SMN2 copies and 10 with 3 SMN2 copies). Baseline and serial right median, ulnar, and fibular motor nerve CMAP amplitudes (millivolts, mV) were obtained during the study. Functional outcomes were assessed using the Children's Hospital of Philadelphia Infant Test of Neuromuscular Disorders (CHOP-INTEND).

RESULTS

At baseline, infants with 2 SMN2 copies demonstrated significantly lower median, ulnar, and fibular CMAP amplitudes compared with infants with 3 SMN2 copies (p < 0.05). In contrast, baseline CHOP-INTEND scores did not differ significantly between the two groups. Prior to genetic confirmation, a right median CMAP amplitude ≥3.2 mV predicted ≥3 SMN2 copies. Following treatment, right median and fibular CMAP amplitudes demonstrated significant improvement over time, including in analyses accounting for SMN2 copies number.

CONCLUSION

CMAP amplitudes obtained from multiple upper- and lower-extremity motor nerves provided objective electrophysiological measures that distinguished infants with two versus three SMN2 copies, despite similar baseline CHOP-INTEND scores. Furthermore, CMAP abnormalities were detectable in some cases before confirmatory genetic testing results became available. Serial CMAP measurements demonstrated significant longitudinal changes following treatment, whereas functional assessments approached ceiling values, supporting the potential value of electrophysiological monitoring in the era of disease-modifying therapies.

SIGNIFICANCE: CMAP assessment is a useful adjunct in the evaluation of infants identified through SMA NBS.

Для цитирования: Samur Bahadir M, Salhotra Ekta Bery, Sadhu Sneha, Bheemisetty Niharika, He Zhulin, Verma Sumit. Compound muscle action potential amplitudes in newborn screen positive spinal muscular atrophy.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2026. DOI: 10.1016/j.clinph.2026.2112353.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.