Superior detection rate of plasma cell FISH using FACS-FISH.

Gagnon Marie-France, Midthun Sally M, Fangel James A, Schuh Cynthia M, Luoma Ivy M, Pearce Kathryn E, Meyer Reid G, Ailawadhi Sikander, Arribas Mariano J, Braggio Esteban, Fonseca Rafael, Rajkumar S Vincent, Zepeda-Mendoza Cinthya, Xu Xinjie, Greipp Patricia T, Timm Michael M, Otteson Gregory E, Shi Min, Jevremovic Dragan, Olteanu Horatiu, Peterson Jess F, Ketterling Rhett P, Kumar Shaji, Baughn Linda B

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Fluorescence in situ hybridization (FISH) for plasma cell neoplasms (PCNs) requires plasma cell (PC) identification or purification strategies to optimize results. We compared the efficacy of cytoplasmic immunoglobulin FISH (cIg-FISH) and fluorescence-activated cell sorting FISH (FACS-FISH) in a clinical laboratory setting.

METHODS

The FISH analysis results of 14,855 samples from individuals with a suspected PCN subjected to cytogenetic evaluation between 2019 and 2022 with cIg-FISH (n = 6917) or FACS-FISH (n = 7938) testing were analyzed.

RESULTS

Fluorescence-activated cell sorting-FISH increased the detection rate of abnormalities in comparison with cIg-FISH, with abnormal results documented in 54% vs 50% of cases, respectively (P < .001). It improved the detection of IGH::CCND1 (P < .001), IGH::MAF (P < .001), IGH::MAFB (P < .001), other IGH rearrangements (P < .001), and gains/amplifications of 1q (P < .001), whereas the detection rates of IGH::FGFR3 fusions (P = .3), loss of 17p (P = .3), and other abnormalities, including hyperdiploidy (P = .5), were similar. Insufficient PC yield for FISH analysis was decreased between cIg-FISH and FACS-FISH (22% and 3% respectively, P < .001). Flow cytometry allowed establishment of ploidy status in 91% of cases. In addition, FACS-FISH decreased analysis times, workload efforts, and operating costs.

CONCLUSIONS

Fluorescence-activated cell sorting-FISH is an efficient PC purification strategy that affords significant improvement in diagnostic yield and decreases workflow requirements in comparison with cIg-FISH.

Для цитирования: Gagnon Marie-France, Midthun Sally M, Fangel James A, Schuh Cynthia M, Luoma Ivy M, Pearce Kathryn E, Meyer Reid G, Ailawadhi Sikander, Arribas Mariano J, Braggio Esteban, Fonseca Rafael, Rajkumar S Vincent, Zepeda-Mendoza Cinthya, Xu Xinjie, Greipp Patricia T, Timm Michael M, Otteson Gregory E, Shi Min, Jevremovic Dragan, Olteanu Horatiu, Peterson Jess F, Ketterling Rhett P, Kumar Shaji, Baughn Linda B. Superior detection rate of plasma cell FISH using FACS-FISH.. American journal of clinical pathology. 2024. DOI: 10.1093/ajcp/aqad108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.