Management of Traumatic Cataract with Posterior Capsular Rupture: A Case Report and In Vitro Model Study.

Wan Wenjuan, Hu Ke, Ji Yan, Li Can

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the optimal strategy for surgical management of traumatic cataract with posterior capsular rupture.

METHODS

We describe four cases of traumatic cataract with posterior capsular rupture and an in vitro model built to evaluate the optimal infusion pressure during surgery.

RESULTS

All patients underwent cataract surgery. By using an anterior chamber maintainer to elevate infusion pressure, we safely performed cataract extraction without phacoemulsification. At 3 days after surgery, visual acuity was greater than 20/25 in all patients, without any complications. Phacoemulsification would also be feasible under anterior chamber maintainer infusion in a similar case of traumatic cataract with posterior capsular rupture during intravitreal injection. In addition, an in vitro model that we established using pig's eyes revealed that the anterior chamber remained stable when the height of infusion bottle was 50-90 mmHg, whereas shallowing of the anterior chamber occurred when the height of infusion bottle was reduced to 40 mmHg, and corneal edema occurred when the height of infusion bottle was raised to 100 mmHg.

CONCLUSIONS

During management of traumatic cataract with posterior capsular rupture, using an anterior chamber maintainer to maintain optimal infusion pressure may reduce the risk of anterior hyaloid membrane breakup and vitreous loss.

Для цитирования: Wan Wenjuan, Hu Ke, Ji Yan, Li Can. Management of Traumatic Cataract with Posterior Capsular Rupture: A Case Report and In Vitro Model Study.. Case reports in ophthalmological medicine. 2017. DOI: 10.1155/2017/4230657.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.