Oral Lipid Nanocrystal Amphotericin B for Cryptococcal Meningitis: A Randomized Clinical Trial.

Boulware David R, Atukunda Mucunguzi, Kagimu Enock, Musubire Abdu K, Akampurira Andrew, Tugume Lillian, Ssebambulidde Kenneth, Kasibante John, Nsangi Laura, Mugabi Timothy, Gakuru Jane, Kimuda Sarah, Kasozi Derrick, Namombwe Suzan, Turyasingura Isaac, Rutakingirwa Morris K, Mpoza Edward, Kigozi Enos, Muzoora Conrad, Ellis Jayne, Skipper Caleb P, Matkovits Theresa, Williamson Peter R, Williams Darlisha A, Fieberg Ann, Hullsiek Kathy H, Abassi Mahsa, Dai Biyue, Meya David B

Рандомизированное исследованиеСтатьяResearch Support, N.I.H., IntramuralПеревод в очереди

Аннотация

BACKGROUND

Amphotericin B is the gold standard treatment for severe mycoses. A new orally delivered, less-toxic formulation of amphotericin has been developed.

METHODS

In our randomized clinical trial, we tested oral lipid nanocrystal (LNC) amphotericin B (MAT2203, Matinas Biopharma) vs intravenous (IV) amphotericin for human immunodeficiency virus-associated cryptococcal meningitis in 4 sequential cohorts. Two pilot cohorts assessed safety and tolerability (n = 10 each), and 2 cohorts assessed efficacy with/without 2 IV loading doses (n = 40 each). The experimental arm received 1.8 g/d oral LNC amphotericin through 2 weeks with 100 mg/kg/d flucytosine, then 1.2 g/d LNC amphotericin through 6 weeks. The randomized control arm (n = 41) received 7 days of IV amphotericin with flucytosine, then 7 days of fluconazole 1200 mg/d. The primary end point was cerebrospinal fluid (CSF) early fungicidal activity (EFA).

RESULTS

We randomized 80 participants to oral LNC amphotericin + flucytosine with (n = 40) and without (n = 40) 2 IV loading doses and 41 control participants to IV amphotericin + flucytosine. Mean EFA was 0.40 log10 colony-forming units (CFU)/mL/d for all-oral LNC amphotericin, 0.42 log10  Cryptococcus CFU/mL/d for oral LNC amphotericin with IV loading doses, and 0.46 log10 CFU/mL/d for IV amphotericin controls. LNC amphotericin groups achieved 2-week CSF sterility in 63% (44 of 70) vs 68% (23 of 34) of controls. The 18-week survival was 85% (34 of 40) with all-oral LNC amphotericin, 90% (36 of 40) with oral LNC amphotericin given IV loading doses, and 85% (35 of 41) with IV amphotericin.Grade 3-4 laboratory adverse events occurred less frequently in LNC amphotericin groups (41%) than the IV amphotericin group (61%, P = .05), particularly for anemia (21% vs 44%; P = .01) and potassium (5% vs 17%; P = .04).

CONCLUSIONS

This new oral amphotericin B LNC formulation appears promising for cryptococcal meningitis with antifungal activity, similar survival, and less toxicity than IV amphotericin.

CLINICAL TRIALS REGISTRATION: NCT04031833.

Для цитирования: Boulware David R, Atukunda Mucunguzi, Kagimu Enock, Musubire Abdu K, Akampurira Andrew, Tugume Lillian, Ssebambulidde Kenneth, Kasibante John, Nsangi Laura, Mugabi Timothy, Gakuru Jane, Kimuda Sarah, Kasozi Derrick, Namombwe Suzan, Turyasingura Isaac, Rutakingirwa Morris K, Mpoza Edward, Kigozi Enos, Muzoora Conrad, Ellis Jayne, Skipper Caleb P, Matkovits Theresa, Williamson Peter R, Williams Darlisha A, Fieberg Ann, Hullsiek Kathy H, Abassi Mahsa, Dai Biyue, Meya David B. Oral Lipid Nanocrystal Amphotericin B for Cryptococcal Meningitis: A Randomized Clinical Trial.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2023. DOI: 10.1093/cid/ciad440.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.