DOI 10.1016/j.jcv.2026.105952

Медицинская библиотека · Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2026

Comparison of influenza hemagglutination inhibition titers from capillary blood versus venipuncture.

Rick Anne-Marie, Costa Rachel, Alcorn John F, Jefferson Stacie, Flannery Brendan, Levine Min Z, Martin Judith M

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Capillary blood self-collection devices offer a minimally invasive alternative to venipuncture, potentially expanding access to serologic studies in outpatient and remote settings. We aimed to evaluate the concordance of influenza HAI titers between capillary blood collected using a minimally invasive device and venous blood collected via standard venipuncture.

METHODS

We compared three paired samples collected from participants during a single visit: venipuncture, staff-assisted capillary device collection (clinic-collect), and participant self-collected capillary device with 72-hour delayed processing (self-collect) to simulate both on-site and at-home blood collection conditions. We compared HAI titers against influenza A(H1N1) antigen across collection methods using Pearson correlation coefficients, Bland-Altman plots, and paired t-tests. Sample volume adequacy and correlation thresholds for clinical interpretability were also assessed.

RESULTS

Among 27 participants, HAI titers correlated strongly between venipuncture and both minimally invasive device approaches (clinic-collect: r = 0.955; self-collect: r = 0.937). Venipuncture titers were modestly higher, with mean differences of + 0.26 log₂ units (clinic-collect) and + 0.35 log₂ units (self-collect); these differences were below the 1-dilution (2-fold) threshold and not clinically meaningful. Most device samples (89-96%) fell within ±1 log₂ unit of venipuncture. On first attempt, 78% of device collections met the ≥ 600 μL volume threshold, increasing to > 93% with use of a second device.

CONCLUSION

Minimally invasive devices yielded influenza HAI titers highly comparable to venipuncture, with clinically acceptable differences in adults. Self-collection with a minimally invasive device could serve as a practical, scalable alternative for serologic studies.

Для цитирования: Rick Anne-Marie, Costa Rachel, Alcorn John F, Jefferson Stacie, Flannery Brendan, Levine Min Z, Martin Judith M. Comparison of influenza hemagglutination inhibition titers from capillary blood versus venipuncture.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2026. DOI: 10.1016/j.jcv.2026.105952.