MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41366-024-01682-5

Медицинская библиотека · International journal of obesity (2005) · 2024

Development of a sex-specific visceral fat area estimation using discrete multi-wavelength near-infrared spectroscopy measurements in Korean individuals.

Ban Soonhyun, Baek Jihyeon, Choi Soee, Han Sung-Ho

СтатьяПеревод в очереди

Аннотация

BACKGROUND/

OBJECTIVES

A high level of visceral fat area (VFA) is associated with obesity and cardiometabolic risk factors. VFA measured by computer tomography (CT) scan is accurate but has limitations for everyday use. Meanwhile, near-infrared (NIR) light penetrates the superficial layers of the human body so that fat content can be measured just as CT imaging measures fat accumulation.

SUBJECTS/

METHODS

This study evaluated whether discrete multi-wavelength NIR spectroscopy (DMW-NIRS) can be used to measure abdominal fat as a satisfactory alternative to a CT scan. 290 subjects were enrolled in this study, and each subject underwent DMW-NIRS NIR measurement and CT scan. A sex-specific DMW-NIRS-based VFA estimation formula was developed by multiple linear regression, including lipid density, age, and body mass index (BMI).

RESULTS

The model of DMW-NIRS estimated VFA gave the least Akaike Information Criterions (AIC), Root Mean Squared Errors (RMSE), and the greatest Coefficient of determination (R2) to predict VFA (1199, 29.5, 0.544 in female, and 1714, 41.3, 0.504 in male, respectively). Also, the DMW-NIRS estimated that VFA was highly performed to determine visceral obesity, which is comparable with other obesity surrogates.

CONCLUSIONS

This study suggested that lipid density can be used as a valid, noninvasive method to determine visceral obesity.

Для цитирования: Ban Soonhyun, Baek Jihyeon, Choi Soee, Han Sung-Ho. Development of a sex-specific visceral fat area estimation using discrete multi-wavelength near-infrared spectroscopy measurements in Korean individuals.. International journal of obesity (2005). 2024. DOI: 10.1038/s41366-024-01682-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.