MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.oftale.2026.502518

Медицинская библиотека · Archivos de la Sociedad Espanola de Oftalmologia · 2026

Assessment of visual performance and quality of life obtained with two extended depth of focus simultaneous vision lens platforms.

de Luis Eguileor B, Santos Zorrozúa B, Etxebarria Ecenarro J

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

INTRODUCTION AND

OBJECTIVES

To assess differences in visual performance after implantation of two extended depth-of-focus simultaneous vision intraocular lenses (IOLs) with different optical designs.

PATIENTS AND

METHODS

A randomised prospective comparative interventional study in patients requiring cataract surgery for both eyes. Patients were divided into two groups: one given biconvex IOLs (Tecnis Eyhance™, Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA) and the other inverted meniscus IOLs (ArtIOLs®25, Voptica, Murcia, Spain). One month after the surgical intervention in the second eye, the binocular distance-corrected visual acuity was measured at far, intermediate (66 cm), and near (40 cm) distances. Additionally, binocular distance-corrected defocus curves were obtained. Potential correlations of intermediate visual acuity (VA) with corneal spherical aberration (Z4°) and pupil size were explored. The Catquest-9SF questionnaire was administered to all patients to assess their vision-related quality of life after IOL implantation.

RESULTS

Overall, 30 patients (60 eyes) were assessed. Binocular distance corrected intermediate visual acuities of 0.20 logMAR (0.10;0.30) (p = 0.445), were achieved in both groups. The binocular distance corrected near visual acuity was 0.3 logMAR (0.25; 0,40) in the Tecnis Eyhance™ group and 0.4 logMAR (0.30;0.50) in the ArtIOLs®25 group (p = 0.050). Intermediate visual acuity was weakly correlated with corneal spherical aberration and pupil size. The Catquest-9SF score was close to 1 in both groups, but better in the Eyhance group, and the difference was statistically significant (p = 0.035).

CONCLUSIONS

Both the Tecnis Eyhance™ and ArtIOLs®25 IOLs achieved a binocular distance-corrected intermediate VA of 0.2 logMAR, without compromising distance VA. No differences were observed between the two groups in the outcomes experienced by patients in their daily lives related to their vision problems after cataract surgery.

Для цитирования: de Luis Eguileor B, Santos Zorrozúa B, Etxebarria Ecenarro J. Assessment of visual performance and quality of life obtained with two extended depth of focus simultaneous vision lens platforms.. Archivos de la Sociedad Espanola de Oftalmologia. 2026. DOI: 10.1016/j.oftale.2026.502518.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.