MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4269/ajtmh.14-0696

Медицинская библиотека · The American journal of tropical medicine and hygiene · 2015

Suitability of capillary blood for quantitative assessment of G6PD activity and performances of G6PD point-of-care tests.

Bancone Germana, Chu Cindy S, Chowwiwat Nongnud, Somsakchaicharoen Raweewan, Wilaisrisak Pornpimon, Charunwatthana Prakaykaew, Bansil Pooja, McGray Sarah, Domingo Gonzalo J, Nosten François H

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The use of primaquine and other 8-aminoquinolines for malaria elimination is hampered by, among other factors, the limited availability of point-of-care tests for the diagnosis of glucose-6-phosphate dehydrogenase (G6PD) deficiency. Historically, the most used source of blood for G6PD analyses is venous blood, whereas diagnostic devices used in the field require the use of capillary blood; data have shown that the two sources of blood often differ with respect to hemoglobin concentration and number of red blood cells. Therefore, we have analyzed, in both capillary and venous blood drawn from the same healthy donors, the correlation of G6PD activity assessed by two qualitative tests (the Fluorescent Spot test and the CareStart test) with the gold standard quantitative spectrophotometric assay. Results obtained on 150 subjects with normal, intermediate, and deficient G6PD phenotypes show that, although differences exist between the aforementioned characteristics in capillary and venous blood, these do not impact on the quantitative assessment of G6PD activity after corrected for hemoglobin concentration or red blood cell count. Furthermore, we have assessed the sensitivity and specificity of the two qualitative tests against the gold standard spectrophotometric assay at different activity thresholds of residual enzymatic activity in both blood sources.

Для цитирования: Bancone Germana, Chu Cindy S, Chowwiwat Nongnud, Somsakchaicharoen Raweewan, Wilaisrisak Pornpimon, Charunwatthana Prakaykaew, Bansil Pooja, McGray Sarah, Domingo Gonzalo J, Nosten François H. Suitability of capillary blood for quantitative assessment of G6PD activity and performances of G6PD point-of-care tests.. The American journal of tropical medicine and hygiene. 2015. DOI: 10.4269/ajtmh.14-0696.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.