MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icb.0000000000001880

Медицинская библиотека · Retinal cases & brief reports · 2026

Four-Point Gore-Tex Scleral Fixation Using A Novel "ALL-IN-ONE" Hydrophilic Acrylic Intraocular Lens With Integrated Eyelets.

Ferreira Bruno Fortaleza de Aquino, Martins João Vitor Bezerra, Sano Ronaldo Yuiti, Regatieri Caio Vinicius Saito, Pimentel Sergio Luis Gianotti

СтатьяКлинический случайПеревод в очереди

Аннотация

PURPOSE: To describe a surgical technique for four-point Gore-Tex scleral fixation of a foldable hydrophilic acrylic intraocular lens (IOL) with integrated eyelets (UnA IOL; Mediphacos, Belo Horizonte, Brazil) and report its postoperative outcomes.

METHODS

A 62-year-old woman presented with persistent monocular diplopia after cataract surgery with in-the-bag implantation of a 3-piece IOL. Examination revealed IOL decentration secondary to zonular dialysis exceeding 120°, accompanied by iridodonesis. The unstable IOL was explanted, and pars plana vitrectomy was performed, followed by implantation of the UnA IOL using a 4-point Gore-Tex CV-8 scleral fixation technique.

RESULTS

Monocular diplopia resolved entirely on the postoperative day, and best-corrected visual acuity improved from 20/30 preoperatively to 20/20 at 1 month, with the IOL well-centered and stable on ultrasound biomicroscopy. No suture erosion, persistent inflammation, ocular hypertension, or macular edema was observed, and the UnA IOL remained well-centered and stable during the 6-month follow-up.

CONCLUSIONS

Four-point Gore-Tex scleral fixation using the UnA IOL demonstrated excellent centration, stability, and safety in the setting of significant zonular loss. Its purpose-built design, foldability, and accessibility make it a practical alternative for secondary IOL implantation in eyes lacking adequate capsular support.

Для цитирования: Ferreira Bruno Fortaleza de Aquino, Martins João Vitor Bezerra, Sano Ronaldo Yuiti, Regatieri Caio Vinicius Saito, Pimentel Sergio Luis Gianotti. Four-Point Gore-Tex Scleral Fixation Using A Novel "ALL-IN-ONE" Hydrophilic Acrylic Intraocular Lens With Integrated Eyelets.. Retinal cases & brief reports. 2026. DOI: 10.1097/icb.0000000000001880.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.