Utilizing 3D-Printed Orbital Floor Stamps to Create Patient-Specific Implants for Orbital Floor Reconstruction.

Prabhu Shamit S, Chung Scotty A, Brown Philip J, Runyan Christopher M

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study seeks to test a novel technique of custom-printed midface contour models with orbital floor "stamps" to guide reconstruction of orbital floor blowout fractures, with or without concomitant zygomaticomaxillary complex injury.

METHODS

A series of 4 consecutive patients with orbital floor blowout fractures (including 3 with zygomatic maxillary complex fractures) were retrospectively examined for outcomes associated with orbital floor reconstruction using 3-dimensional-printed stamps and midface models. Data collected included demographics, pre- and postoperative visual globe malposition, motility, and visual field disturbances. Three-dimensional printing methodology is reported, as well as associated costs and time required to generate the models and stamps.

RESULTS

The cost of producing a midface-contour model and orbital floor stamps was $131, inclusive of labor and materials. Cases averaged 170 minutes to segment, design, and print. Patients with preoperative diplopia and motility restrictions had resolution of their symptoms. Two patients had resolution of their enophthalmos, while one patient with a concomitant zygomaticomaxillary fracture had persistent mild enophthalmos.

CONCLUSIONS

Midface contour models and orbital floor stamps may be produced in a timely and cost-effective manner. Use of these "homemade" stamps allows for patient-specific custom-contoured orbital floor reconstruction. Further studies are warranted to examine long-term visual and esthetic outcomes for these patients.

Для цитирования: Prabhu Shamit S, Chung Scotty A, Brown Philip J, Runyan Christopher M. Utilizing 3D-Printed Orbital Floor Stamps to Create Patient-Specific Implants for Orbital Floor Reconstruction.. Ophthalmic plastic and reconstructive surgery. 2021. DOI: 10.1097/iop.0000000000001734.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.