MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.xops.2026.101313

Медицинская библиотека · Ophthalmology science · 2026

Association between Circulating Ketone Bodies and Primary Open-Angle Glaucoma and Related Ocular Parameters.

Chen Jianqi, Wang Zhirong, Deng Shuifeng, Li Zhidong, Chen Xiaohong, Liang Jingying, Li Yuke, Yu Jianhong, Lei Lei, Zhuo Yehong, Zhu Yingting

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Ketone bodies are key metabolic intermediates with both neuroprotective and pro-oxidative properties; however, their role in glaucoma remains unclear. This study aimed to investigate associations between circulating ketone bodies and the incidence of primary open-angle glaucoma (POAG), as well as related ocular parameters, in the UK Biobank.

DESIGN

Combined cross-sectional analysis and prospective cohort study.

PARTICIPANTS

A total of 456 499 participants were included in the cohort analysis; 104 225 were included in the baseline intraocular pressure (IOP) analysis, 41 495 in the baseline ganglion cell complex (GCC) thickness analysis, and 39 498 in the IOP-adjusted GCC thickness analysis.

METHODS

Circulating ketone bodies were quantified using nuclear magnetic resonance-based metabolomics. Cox proportional hazards models were used to estimate hazard ratios for POAG incidence. Linear regression models assessed associations with baseline IOP and GCC thickness. Restricted cubic spline models were applied to evaluate dose-response relationships, and subgroup analyses were conducted to explore potential effect modification.

MAIN OUTCOME MEASURES: Incidence of POAG.

RESULTS

During follow-up, 2330 participants developed POAG. Higher circulating ketone body levels were associated with an increased incidence of POAG after full adjustment (hazard ratio: 1.93, 95% confidence interval [CI]: 1.25-2.99, P = 0.003). Elevated ketone body levels were also associated with higher baseline IOP (β = 1.84, 95% CI: 1.57-2.10, P < 0.001) and thinner GCC both before (β = -1.62, 95% CI: -2.66 to -0.57, P = 0.002) and after IOP adjustment (β = -1.48, 95% CI: -2.53 to -0.42, P = 0.006), suggesting associations that are partially IOP-independent.

CONCLUSIONS

Elevated circulating ketone body levels were associated with a higher incidence of POAG and related ocular phenotypes. Circulating ketone body levels may serve as a potential biomarker of systemic metabolic dysregulation associated with increased POAG susceptibility.Financial Disclosure(s)Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Для цитирования: Chen Jianqi, Wang Zhirong, Deng Shuifeng, Li Zhidong, Chen Xiaohong, Liang Jingying, Li Yuke, Yu Jianhong, Lei Lei, Zhuo Yehong, Zhu Yingting. Association between Circulating Ketone Bodies and Primary Open-Angle Glaucoma and Related Ocular Parameters.. Ophthalmology science. 2026. DOI: 10.1016/j.xops.2026.101313.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.