MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fmicb.2016.00554

Медицинская библиотека · Frontiers in microbiology · 2016

Visual Detection of West Nile Virus Using Reverse Transcription Loop-Mediated Isothermal Amplification Combined with a Vertical Flow Visualization Strip.

Cao Zengguo, Wang Hualei, Wang Lina, Li Ling, Jin Hongli, Xu Changping, Feng Na, Wang Jianzhong, Li Qian, Zhao Yongkun, Wang Tiecheng, Gao Yuwei, Lu Yiyu, Yang Songtao, Xia Xianzhu

СтатьяПеревод в очереди

Аннотация

West Nile virus (WNV) causes a severe zoonosis, which can lead to a large number of casualties and considerable economic losses. A rapid and accurate identification method for WNV for use in field laboratories is urgently needed. Here, a method utilizing reverse transcription loop-mediated isothermal amplification combined with a vertical flow visualization strip (RT-LAMP-VF) was developed to detect the envelope (E) gene of WNV. The RT-LAMP-VF assay could detect 10(2) copies/μl of an WNV RNA standard using a 40 min amplification reaction followed by a 2 min incubation of the amplification product on the visualization strip, and no cross-reaction with other closely related members of the Flavivirus genus was observed. The assay was further evaluated using cells and mouse brain tissues infected with a recombinant rabies virus expressing the E protein of WNV. The assay produced sensitivities of 10(1.5) TCID50/ml and 10(1.33) TCID50/ml for detection of the recombinant virus in the cells and brain tissues, respectively. Overall, the RT-LAMP-VF assay developed in this study is rapid, simple and effective, and it is therefore suitable for clinical application in the field.

Для цитирования: Cao Zengguo, Wang Hualei, Wang Lina, Li Ling, Jin Hongli, Xu Changping, Feng Na, Wang Jianzhong, Li Qian, Zhao Yongkun, Wang Tiecheng, Gao Yuwei, Lu Yiyu, Yang Songtao, Xia Xianzhu. Visual Detection of West Nile Virus Using Reverse Transcription Loop-Mediated Isothermal Amplification Combined with a Vertical Flow Visualization Strip.. Frontiers in microbiology. 2016. DOI: 10.3389/fmicb.2016.00554.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.