Transcatheter Valve Replacement in Carcinoid Heart Disease: A Potential Change of Paradigm.
Аннотация
OBJECTIVES
To evaluate the feasibility and early clinical outcomes of transcatheter valve replacement in high-surgical-risk patients with carcinoid heart disease.
MATERIALS AND
METHODS
This study included 15 procedures performed in 9 patients with symptomatic carcinoid heart disease between 2021 and 2025. Valve involvement included the pulmonary valve in 9 cases, the tricuspid valve in 5 cases, and the aortic valve in 1 case. Valve selection (SAPIEN 3, TOPAZ, LUX) was individualized according to anatomical considerations. All 9 patients received intravenous periprocedural octreotide. Outcomes included procedural success, NYHA class, and echocardiographic evaluation of valve and ventricular function.
RESULTS
Single-valve replacement was performed in 4 patients (2 pulmonary and 2 tricuspid). Double-valve replacement involving the pulmonary and tricuspid valves was performed in 4 patients, and 1 patient underwent triple-valve replacement (aortic, pulmonary, and tricuspid). One high-risk patient required conversion after a tricuspid procedure but ultimately recovered after a prolonged hospital stay. At a median follow-up of 9.9 months (IQR 3.5), all patients showed clinical improvement. One patient developed a transient tricuspid paravalvular thrombus without dysfunction or clinical consequence. Echocardiography demonstrated a reduction in right ventricular diameter. No case of endocarditis was observed. One patient died 4 months post-procedure from tumour progression.
CONCLUSIONS
This first series of transcatheter valve replacements in carcinoid heart disease suggests that a complete percutaneous approach is feasible, safe, and potentially beneficial. These early results warrant confirmation in larger cohorts with longer follow-up and may represent a paradigm shift in the management of carcinoid valve disease.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.