MedElevator Войти в исследования
← Поиск публикаций

DOI 10.57264/cer-2025-0151

Медицинская библиотека · Journal of comparative effectiveness research · 2026

Difference in hospital readmission among patients with atrial fibrillation undergoing ablation using nonintegrated pulsed field catheter with CARTO™ 3 versus EnSite™ electroanatomical mapping system.

Costea Alexandru I, Khanna Rahul, Iglesias Maximiliano, Rong Yiran

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Aim: Pulsed field ablation (PFA) is a minimally thermal alternative to traditional thermal catheter ablation for atrial fibrillation (AF), with comparable efficacy and minimal risk of collateral tissue injury. Three-dimensional (3D) electroanatomical mapping systems have been adopted with nonintegrated PFA catheters to improve precision and procedural efficiency. This study compared arrhythmia-related hospital readmissions and procedure-related complications among patients with AF treated with PFA, using either the CARTO™ 3 or EnSite™ electroanatomical mapping system. Materials & methods: Patients who underwent PFA for AF using nonintegrated pulsed field catheters with either CARTO 3 or EnSite were identified from the 2023-2024 Premier Healthcare Database (PHD). The primary outcome was 30-day inpatient readmission and emergency room (ER) visit for AF/atrial flutter (AFL)/atrial tachycardia following the index PFA procedure. Secondary outcomes included 30-day cardiovascular-related readmissions and procedure-related complications. Cohorts were balanced using inverse probability of treatment weighting. Descriptive analyses and a weighted Generalized Estimating Equation (GEE) model were used to assess differences in outcomes between groups.

Results

A total of 2894 patients were treated using CARTO 3 and 2015 using EnSite. After weighting, patient and hospital characteristics were well balanced across cohorts. The CARTO 3 group was significantly less likely to experience AF/AFL/atrial tachycardia-related readmissions (0.3% vs 0.9%, chi-square p = 0.023; odds ratio [OR], 0.39; 95% CI, 0.17-0.90, GEE p = 0.028) and a composite outcome of AF/AFL/atrial tachycardia-related inpatient readmission or ER visits (0.5% vs 1.1%, chi-square p = 0.020; OR: 0.44, 95% CI: 0.21-0.89, GEE p = 0.023) within 30 days of PFA procedure than the EnSite group. No differences were observed in cardiovascular-related readmission or complications.

Conclusion

In this retrospective, real-world study, patients with AF who underwent PFA using CARTO 3 had lower 30-day AF/AFL/atrial tachycardia-related readmissions rates than those treated with EnSite suggesting that choice of mapping system may influence early AF outcomes and could translate into reduced downstream hospitalizations and resource use.

Для цитирования: Costea Alexandru I, Khanna Rahul, Iglesias Maximiliano, Rong Yiran. Difference in hospital readmission among patients with atrial fibrillation undergoing ablation using nonintegrated pulsed field catheter with CARTO™ 3 versus EnSite™ electroanatomical mapping system.. Journal of comparative effectiveness research. 2026. DOI: 10.57264/cer-2025-0151.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.