Case reports in ophthalmology · 2024
Pseudophakic Pupillary Block due to the Capsular Bag Intraocular Lens Implant Located in the Sulcus: A Case Report.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bade Yusuf, Dossantos Jason, Hong Alison, Dar Salman, Belyea David
Аннотация
INTRODUCTION: Pupillary block, a concerning complication of cataract surgery, is heightened when a single-piece acrylic (SPA) intraocular lens (IOL) is implanted in the ciliary sulcus. We report an unusual occurrence of relative pupillary block and chronic angle-closure glaucoma (ACG) identified in the late postoperative period due to unintentional SPA IOL implantation in the sulcus.
CASE PRESENTATION: An 82-year-old woman presented with a history of chronic ACG 5 years after bilateral cataract extraction. Postoperatively, she experienced anterior chamber shallowing, elevated intraocular pressure (IOP), and two acute angle-closure attacks in the left eye, successfully managed with laser peripheral iridotomies (LPIs). Despite neodymium:YAG capsulotomy, elevated IOP persisted. Maximal medical therapy effectively controlled IOP; however, a shallow anterior chamber remained, prompting referral to our glaucoma service. Slit-lamp examination revealed a shallow peripheral anterior chamber, patent LPIs, and an Alcon SA60WF SPA IOL situated posteriorly with the optic against the pupil margin OS. Gonioscopy indicated a closed angle with peripheral anterior synechiae (PAS). Ultrasound biomicroscopy (UBM) confirmed haptics in the sulcus, with the lens optic and haptics anterior to the bag. These findings suggest relative pupillary block as the cause of her chronic ACG. The SPA IOL's bulky haptics in the sulcus likely induced iris bowing, leading to prolonged appositional angle-closure and chronic PAS formation.
CONCLUSION: IOLs designed for the capsular bag should not be placed in the sulcus. Therefore, IOLs of varying dimensions should be taken to the operating room in the event of complicated cataract extraction. Finally, UBM proves valuable in identifying causes of pupillary block.
CASE PRESENTATION: An 82-year-old woman presented with a history of chronic ACG 5 years after bilateral cataract extraction. Postoperatively, she experienced anterior chamber shallowing, elevated intraocular pressure (IOP), and two acute angle-closure attacks in the left eye, successfully managed with laser peripheral iridotomies (LPIs). Despite neodymium:YAG capsulotomy, elevated IOP persisted. Maximal medical therapy effectively controlled IOP; however, a shallow anterior chamber remained, prompting referral to our glaucoma service. Slit-lamp examination revealed a shallow peripheral anterior chamber, patent LPIs, and an Alcon SA60WF SPA IOL situated posteriorly with the optic against the pupil margin OS. Gonioscopy indicated a closed angle with peripheral anterior synechiae (PAS). Ultrasound biomicroscopy (UBM) confirmed haptics in the sulcus, with the lens optic and haptics anterior to the bag. These findings suggest relative pupillary block as the cause of her chronic ACG. The SPA IOL's bulky haptics in the sulcus likely induced iris bowing, leading to prolonged appositional angle-closure and chronic PAS formation.
CONCLUSION: IOLs designed for the capsular bag should not be placed in the sulcus. Therefore, IOLs of varying dimensions should be taken to the operating room in the event of complicated cataract extraction. Finally, UBM proves valuable in identifying causes of pupillary block.