Z-suture scleral fixation intraocular lenses: A refractive and safety report.

Barbosa Renato Correia, Carvalho Rui

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: Scleral fixation of intraocular lenses constitutes a surgical option in cases where there is inadequate capsular support or zonular insufficiency. Knotless techniques, such as the z-suture technique, avoid suture-related complications, such as conjunctival erosion or exposure. The purpose of this study was to evaluate the visual outcomes and postoperative complications of patients who underwent scleral z-suture fixation of the Akreos AO® intraocular lenses.

METHODS

A retrospective, observational study was conducted, including 22 eyes of 20 patients who underwent Akreos AO® intraocular lenses using the z- suture scleral fixation technique.

RESULTS

The mean age of the patients was 55,64 ± 28,47 years old, and the mean follow-up time was 25,64 months. The most common indication for surgery was previous complicated cataract surgey. The mean postoperative spherical equivalent was +0,058D ± 0,79D, with values ranging from - 1,50D to +1,00D. Mean best-corrected visual acuity was 0,178 ± 0,15 logMAR. Intraocular pressure was 15,07 ± 2,56 mmHg on the day after surgery, and 16 ± 2,15 mmHg 1 month after. No suture-related complications were observed in any patient postoperatively. One patient had a slight inferonasal lens dislocation and another patient had a severe case of herpetic keratitis posoperatively.

DISCUSSION: The knotless z-suture technique appears to be a reliable and safe way to fix an intraocular lens in the sclera, regardless of the patient's age. Our results show good visual results and predictable refractive outcomes. Decades of follow-up may be necessary to assess the long-term risk of lens dislocation.

Для цитирования: Barbosa Renato Correia, Carvalho Rui. Z-suture scleral fixation intraocular lenses: A refractive and safety report.. European journal of ophthalmology. 2024. DOI: 10.1177/11206721241230566.