Shah Palak, Pischel Lauren, Sack Brady, Abdul Basith K M, Dauphinais Madolyn Rose, Jain Komal, Martins Maria Florencia, Wallace Sierra, Karoly Meagan, Lakshminarayanan Subitha, Cintron Chelsie, Subramanian Sadhana, Sahay Apratim, Koura Kobto G, Brooks Ralph, Shenoi Sheela, Chinnakali Palanivel, Sinha Pranay
Аннотация
OBJECTIVES: Rising global temperatures are expected to increase time individuals spend in under-ventilated spaces and to increase transmission of respiratory pathogens. We studied the impact of ventilation on transmission potential and basic reproductive number (R0) of respiratory viruses in Puducherry, India.
METHODS: We measured ventilation in thirteen homes and seven healthcare offices. We applied the Wells-Riley equation to estimate the transmission potential and R0 of SARS-CoV-2 and influenza under different ventilation conditions and viral shedding levels.
RESULTS: Viral transmission potential was high when doors and windows were closed and highest in the air conditioned (AC) condition. Transmission potential decreased significantly with natural ventilation. R₀ equaled or exceeded 2 in the closed and AC conditions for medium and high virus shedders.
CONCLUSION: The transmission potential of respiratory viruses in underventilated homes and healthcare spaces is high, particularly with AC use. Natural ventilation does not reduce R0 below 1 for super shedders.
METHODS: We measured ventilation in thirteen homes and seven healthcare offices. We applied the Wells-Riley equation to estimate the transmission potential and R0 of SARS-CoV-2 and influenza under different ventilation conditions and viral shedding levels.
RESULTS: Viral transmission potential was high when doors and windows were closed and highest in the air conditioned (AC) condition. Transmission potential decreased significantly with natural ventilation. R₀ equaled or exceeded 2 in the closed and AC conditions for medium and high virus shedders.
CONCLUSION: The transmission potential of respiratory viruses in underventilated homes and healthcare spaces is high, particularly with AC use. Natural ventilation does not reduce R0 below 1 for super shedders.