MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivae086

Медицинская библиотека · Interdisciplinary cardiovascular and thoracic surgery · 2024

Repaired coarctation of the aorta does not affect four-dimensional flow metrics in bicuspid aortic valve disease.

Kiljander Teemu, Kauhanen Petteri, Sillanmäki Saara, Lottonen-Raikaslehto Line, Husso Minna, Ylä-Herttuala Elias, Saari Petri, Kokkonen Jorma, Laukkanen Jari, Mustonen Pirjo, Hedman Marja

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The objective of this study was primarily to compare four-dimensional flow magnetic resonance imaging metrics in the ascending aorta (AA) of patients with right-left fusion type bicuspid aortic valve (RL-BAV) and repaired coarctation of the aorta (CoA) to RL-BAV without CoA. Metrics of patients with RL-BAV were also compared to the matched group of patients with common tricuspid aortic valve (TAV).

METHODS

Eleven patients with RL-BAV and CoA, 11 patients with RL-BAV without CoA and 22 controls with TAV were investigated. Peak velocity (cm/s), peak flow (ml/s) and flow displacement (%) were analysed at 5 pre-defined AA levels. In addition, regional wall shear stress (WSS, mN/m2), circumferential WSS (WSSc) and axial WSS (WSSa) at all levels were quantified in 6 sectors of the aortic circle. Averaged WSS values on each level (WSSavg, WSSc, avg and WSSa, avg) were calculated as well.

RESULTS

Peak velocity at the proximal tubular AA was significantly lower in BAV and CoA group (P = 0.047) compared to BAV without CoA. In addition, the WSSa, avg was found to be higher for the BAV and CoA group at proximal AA respectively (P = 0.040). No other significant differences were found between these groups. BAV group's peak velocity was higher at every level (P < 0.001-0.004) compared to TAV group. Flow displacement was significantly higher for the BAV group at every level (P < 0.001) besides at the most distal level. All averaged WSS values were significantly higher in BAV patients in distal AA (P < 0.001-0.018).

CONCLUSIONS

Repaired CoA does not relevantly alter four-dimensional flow metrics in the AA of patients with RL-BAV. However, RL-BAV majorly alters flow dynamics in the AA when compared to patients with TAV.

CLINICAL TRIAL REGISTRATION NUMBER: https://www.clinicaltrials.gov/study/NCT05065996, Unique Protocol ID 5063566.

Для цитирования: Kiljander Teemu, Kauhanen Petteri, Sillanmäki Saara, Lottonen-Raikaslehto Line, Husso Minna, Ylä-Herttuala Elias, Saari Petri, Kokkonen Jorma, Laukkanen Jari, Mustonen Pirjo, Hedman Marja. Repaired coarctation of the aorta does not affect four-dimensional flow metrics in bicuspid aortic valve disease.. Interdisciplinary cardiovascular and thoracic surgery. 2024. DOI: 10.1093/icvts/ivae086.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.