DOI 10.1097/rli.0000000000001140
Improved MR Detection of Optic Nerve Demyelination With MP2RAGE-FLAWS Compared With T 2 -Weighted Fat-Saturated Sequences.
Аннотация
OBJECTIVES
Nonenhanced T 1 -w sequences such as magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) and derived fluid and white matter suppression (FLAWS) have demonstrated high performance for detecting brain parenchymal and cervical spine demyelinating lesions in multiple sclerosis. However, their potential for identifying optic nerve (ON) demyelination remains unexplored. The aim of this study was to evaluate the performance of compressed sensing-accelerated (CS) MP2RAGE-FLAWS imaging for detection of ON demyelination lesions compared with T2-w fat-saturated (FS) TSE imaging in a clinical setting.
MATERIALS AND
METHODS
We conducted a retrospective study of magnetic resonance scans acquired on patients with central nervous system demyelinating disorders between January and December 2022. Inclusion criteria were the acquisition in the same session of a brain CS-MP2RAGE-FLAWS imaging and a combination of axial + coronal T2-w FS orbital sequences. A 4-step radiological analysis-including blinded and consensus readings-assessed ON lesion detection. The reference standard was the final reading session of radiologists using the entire patient file. Sensitivities and specificities of both sequences were computed and compared using McNemar χ 2 tests.
RESULTS
Thirty-nine patients (mean age: 43 ± 14 years; 25 women) were analyzed, including 34 with multiple sclerosis, 2 with MOGAD (myelin oligodendrocyte glycoprotein antibody-associated disease), 1 with NMOSD (neuromyelitis optica spectrum disorder), and 2 with indeterminate demyelinating disease. Among the 78 ONs analyzed, 64 lesions were detected with CS-MP2RAGE-FLAWS as opposed to 37 with 2D T2-w FS imaging, corresponding to a total of 41 and 27 affected nerves, respectively. CS-MP2RAGE-FLAWS exhibited higher sensitivity for overall detection of ON lesions compared with 2D T2-w FS imaging (97.5% vs 67.5%, P = 0.001) without reducing the specificity. Improved lesion detectability with CS-MP2RAGE-FLAWS was significant compared with 2D T2-w FS in intraorbital and intracanalicular segments (respectively, 92.3% vs 50% and 96.3% vs 66.7%; P < 0.05). There was no difference in sensitivity ( P = 0.69) or specificity ( P = 0.99) regarding the intracranial segment analysis.
CONCLUSIONS
CS-MP2RAGE-FLAWS sequence improves ON lesion detection compared with conventional 2D T2-w FS, especially in the intraorbital segment, while simultaneously providing whole-brain and cervical spinal cord imaging at no additional time cost.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.