MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/biomedicines14092005

Медицинская библиотека · Biomedicines · 2026

An Anesthesia-Free Pharmacological Assay for Zebrafish Heart Failure Models Using a Microfluidic Platform.

Song Qiuyue, Liu Fangrui, Zhao Jinyan, Xie Wenli, Fu Xianjun, Xu Kuo

СтатьяПеревод в очереди

Аннотация

Background

The zebrafish model is extensively utilized for phenotypic screening, particularly in heart failure research. However, traditional photography-based data collection requires tricaine methanesulfonate (MS-222) anesthesia, which can suppress cardiac function and introduce artifacts. This study presents a microfluidic platform designed to facilitate anesthesia-free, noninvasive in vivo photography of zebrafish heart failure models.

Methods

Isoproterenol (ISO) induced heart failure in 1 day post-fertilization (dpf) zebrafish embryos. Larvae were assigned to three groups: Control (E3 embryo medium only), Model (1 mM ISO for 48 h from 1 dpf), and Positive (1 mM ISO + 10 μM propranolol for 48 h from 1 dpf). Subsequently, a microfluidic chip featuring tapered immobilization channels was adopted. The chip facilitated the photography and collection of cardiac function parameters from lateral and supine positions, including cardiac output (CO), blood flow velocity (BFV), ejection fraction (EF), stroke volume (SV), and fractional shortening (FS). All imaging was performed in completely independent parallel experiments, with no individual larva shared between the two imaging methods. Data obtained under hydrodynamic confinement were compared with those acquired under MS-222 anesthesia.

Results

Cardiac parameters measured using the microfluidic platform were significantly higher than those under MS-222 anesthesia: CO (0.339 ± 0.032 vs. 0.279 ± 0.023 nL/s, p < 0.001), BFV (681 ± 53 vs. 604 ± 38 μm/s, p < 0.001), EF (10.3 ± 0.7% vs. 6.6 ± 0.7%, p < 0.001), SV (184,519 ± 12,822 vs. 97,979 ± 5306 μm3, p < 0.001), and FS (7.3 ± 1.8% vs. 3.7 ± 0.9%, p < 0.001). Strong correlations (R2 > 0.85, p < 0.0001) revealed that anesthesia underestimated parameters by 11.3-49.3%.

Conclusions

Compared with the traditional anesthesia-based method, the microfluidic platform enables more precise cardiac parameter collection in a zebrafish heart failure model than when anesthesia is used, offering a reliable tool for phenotypic screening of zebrafish embryos.

Для цитирования: Song Qiuyue, Liu Fangrui, Zhao Jinyan, Xie Wenli, Fu Xianjun, Xu Kuo. An Anesthesia-Free Pharmacological Assay for Zebrafish Heart Failure Models Using a Microfluidic Platform.. Biomedicines. 2026. DOI: 10.3390/biomedicines14092005.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.