MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2010.12.059

Медицинская библиотека · Journal of cataract and refractive surgery · 2011

Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: effect on posterior capsule opacification.

Iwase Takeshi, Nishi Yutarou, Oveson Brian C, Jo Young-Joon

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate posterior capsule opacification (PCO) 2 years after cataract surgery with implantation of a hydrophobic acrylic or single-piece sharp-edged hydrophilic acrylic intraocular lens (IOL).

SETTING

Toyama Prefectural Central Hospital, Toyama, Japan.

DESIGN

Case-control study.

METHODS

Patients with bilateral senile cataract were prospectively randomized to receive a hydrophobic IOL (Acrysof SA60AT) in 1 eye and a hydrophilic IOL (Meridian HP60M) in the other eye. The PCO density value, degree of IOL decentration and tilt, and anterior chamber depth (ACD) were measured using Scheimpflug videophotography 1, 6, 12, 18, and 24 months after surgery. Visual acuity and the number of eyes requiring neodymium:YAG laser capsulotomy were also assessed.

RESULTS

The study evaluated 16 eyes (63 patients). The PCO value in the hydrophilic group increased significantly with time and was statistically significantly greater than in the hydrophobic group 18 and 24 months postoperatively (both P < .001). The capsulotomy rate was statistically significantly higher in the hydrophilic group than in the hydrophobic group (P < .01). Visual acuity in the hydrophilic group worsened significantly with time and was statistically significantly worse than in the hydrophobic group at 18 and 24 months (both P < .001). Intraocular lens decentration, IOL tilt, and the ACD did not change significantly during the follow-up in either group (P > .05), and there were no statistically significant postoperative differences in these parameters between the 2 IOL groups (P > .05).

CONCLUSION

Two years after surgery, the hydrophobic IOL group had less PCO, a lower capsulotomy rate, and better visual acuity than the hydrophilic IOL group.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Iwase Takeshi, Nishi Yutarou, Oveson Brian C, Jo Young-Joon. Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: effect on posterior capsule opacification.. Journal of cataract and refractive surgery. 2011. DOI: 10.1016/j.jcrs.2010.12.059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.