Ramos-Prada Alba, Redondo-Rodríguez Andrés, Roca-Luque Ivo, Porta-Sánchez Andreu, Ter Bekke Rachel M A, Quintanilla Jorge G, Sánchez-González Javier, Peinado Rafael, Merino Jose Luis, Cluitmans Matthijs, Holtackers Robert J, Marina-Breysse Manuel, Galán-Arriola Carlos, Enríquez-Vázquez Daniel, Vázquez-Calvo Sara, Alfonso-Almazán José Manuel, Pizarro Gonzalo, Ibáñez Borja, González-Ferrer Juan José, Salgado-Aranda Ricardo, Cañadas-Godoy Victoria, Calvo David, Pérez-Villacastín Julián, Pérez-Castellano Nicasio, Filgueiras-Rama David
Аннотация
METHODS AND RESULTS: This is a translational study including 18 pigs with established myocardial infarction and inducible VT undergoing in vivo characterization of the anatomical and functional myocardial substrate associated with VT maintenance. Clinical validation was conducted in a multicentre series of 33 patients with ischaemic cardiomyopathy undergoing VT ablation. Three-dimensional LGE-CMR images were processed using systematic scanning of 15 signal intensity (SI) cut-off ranges to obtain surface visualization of all potential VT corridors. Analysis and comparisons of imaging and electrophysiological data were performed in individuals with full electrophysiological characterization of the isthmus sites of at least one VT morphology. In both the experimental pig model and patients undergoing VT ablation, all the electrophysiologically defined isthmus sites (n = 11 and n = 19, respectively) showed overlapping regions with CMR-based potential VT corridors. Such imaging-based VT corridors were less specific than electrophysiologically guided ablation lesions at critical isthmus sites. However, an optimized strategy using the 7 most relevant SI cut-off ranges among patients showed an increase in specificity compared to using 15 SI cut-off ranges (70 vs. 62%, respectively), without diminishing the capability to detect VT isthmus sites (sensitivity 100%).
CONCLUSION: Systematic imaging processing of LGE-CMR sequences using several SI cut-off ranges may improve and standardize procedure planning to identify VT isthmus sites.