MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euae244

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024

Novel systematic processing of cardiac magnetic resonance imaging identifies target regions associated with infarct-related ventricular tachycardia.

Ramos-Prada Alba, Redondo-Rodríguez Andrés, Roca-Luque Ivo, Porta-Sánchez Andreu, Ter Bekke Rachel M A, Quintanilla Jorge G, Sánchez-González Javier, Peinado Rafael, Merino Jose Luis, Cluitmans Matthijs, Holtackers Robert J, Marina-Breysse Manuel, Galán-Arriola Carlos, Enríquez-Vázquez Daniel, Vázquez-Calvo Sara, Alfonso-Almazán José Manuel, Pizarro Gonzalo, Ibáñez Borja, González-Ferrer Juan José, Salgado-Aranda Ricardo, Cañadas-Godoy Victoria, Calvo David, Pérez-Villacastín Julián, Pérez-Castellano Nicasio, Filgueiras-Rama David

СтатьяМногоцентровое исследованиеВалидационное исследованиеПеревод в очереди

Аннотация

AIMS: There is lack of agreement on late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) imaging processing for guiding ventricular tachycardia (VT) ablation. We aim at developing and validating a systematic processing approach on LGE-CMR images to identify VT corridors that contain critical VT isthmus sites.

METHODS AND

RESULTS

This is a translational study including 18 pigs with established myocardial infarction and inducible VT undergoing in vivo characterization of the anatomical and functional myocardial substrate associated with VT maintenance. Clinical validation was conducted in a multicentre series of 33 patients with ischaemic cardiomyopathy undergoing VT ablation. Three-dimensional LGE-CMR images were processed using systematic scanning of 15 signal intensity (SI) cut-off ranges to obtain surface visualization of all potential VT corridors. Analysis and comparisons of imaging and electrophysiological data were performed in individuals with full electrophysiological characterization of the isthmus sites of at least one VT morphology. In both the experimental pig model and patients undergoing VT ablation, all the electrophysiologically defined isthmus sites (n = 11 and n = 19, respectively) showed overlapping regions with CMR-based potential VT corridors. Such imaging-based VT corridors were less specific than electrophysiologically guided ablation lesions at critical isthmus sites. However, an optimized strategy using the 7 most relevant SI cut-off ranges among patients showed an increase in specificity compared to using 15 SI cut-off ranges (70 vs. 62%, respectively), without diminishing the capability to detect VT isthmus sites (sensitivity 100%).

CONCLUSION

Systematic imaging processing of LGE-CMR sequences using several SI cut-off ranges may improve and standardize procedure planning to identify VT isthmus sites.

Для цитирования: Ramos-Prada Alba, Redondo-Rodríguez Andrés, Roca-Luque Ivo, Porta-Sánchez Andreu, Ter Bekke Rachel M A, Quintanilla Jorge G, Sánchez-González Javier, Peinado Rafael, Merino Jose Luis, Cluitmans Matthijs, Holtackers Robert J, Marina-Breysse Manuel, Galán-Arriola Carlos, Enríquez-Vázquez Daniel, Vázquez-Calvo Sara, Alfonso-Almazán José Manuel, Pizarro Gonzalo, Ibáñez Borja, González-Ferrer Juan José, Salgado-Aranda Ricardo, Cañadas-Godoy Victoria, Calvo David, Pérez-Villacastín Julián, Pérez-Castellano Nicasio, Filgueiras-Rama David. Novel systematic processing of cardiac magnetic resonance imaging identifies target regions associated with infarct-related ventricular tachycardia.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2024. DOI: 10.1093/europace/euae244.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.