m+Medelevator.RU
← Поиск публикаций
Cancer science · 2015

Chemokine (C-C motif) ligand 3 detection in the serum of persons exposed to asbestos: A patient-based study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xu Jiegou, Alexander David B, Iigo Masaaki, Hamano Hirokazu, Takahashi Satoru, Yokoyama Takako, Kato Munehiro, Usami Ikuji, Tokuyama Takeshi, Tsutsumi Masahiro, Tamura Mouka, Oguri Tetsuya, Niimi Akio, Hayashi Yoshimitsu, Yokoyama Yoshifumi, Tonegawa Ken, Fukamachi Katsumi, Futakuchi Mitsuru, Sakai Yuto, Suzui Masumi, Kamijima Michihiro, Hisanaga Naomi, Omori Toyonori, Nakae Dai, Hirose Akihiko, Kanno Jun, Tsuda Hiroyuki

Аннотация

Exposure to asbestos results in serious risk of developing lung and mesothelial diseases. Currently, there are no biomarkers that can be used to diagnose asbestos exposure. The purpose of the present study was to determine whether the levels or detection rate of chemokine (C-C motif) ligand 3 (CCL3) in the serum are elevated in persons exposed to asbestos. The primary study group consisted of 76 healthy subjects not exposed to asbestos and 172 healthy subjects possibly exposed to asbestos. The secondary study group consisted of 535 subjects possibly exposed to asbestos and diagnosed with pleural plaque (412), benign hydrothorax (10), asbestosis (86), lung cancer (17), and malignant mesothelioma (10). All study subjects who were possibly exposed to asbestos had a certificate of asbestos exposure issued by the Japanese Ministry of Health, Labour and Welfare. For the primary study group, levels of serum CCL3 did not differ between the two groups. However, the detection rate of CCL3 in the serum of healthy subjects possibly exposed to asbestos (30.2%) was significantly higher (P < 0.001) than for the control group (6.6%). The pleural plaque, benign hydrothorax, asbestosis, and lung cancer groups had serum CCL3 levels and detection rates similar to that of healthy subjects possibly exposed to asbestos. The CCL3 chemokine was detected in the serum of 9 of the 10 patients diagnosed with malignant mesothelioma. Three of the patients with malignant mesothelioma had exceptionally high CCL3 levels. Malignant mesothelioma cells from four biopsy cases and an autopsy case were positive for CCL3, possibly identifying the source of the CCL3 in the three malignant mesothelioma patients with exceptionally high serum CCL3 levels. In conclusion, a significantly higher percentage of healthy persons possibly exposed to asbestos had detectable levels of serum CCL3 compared to healthy unexposed control subjects.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты