MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics15101235

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2025

Prediction of Cardiac Arrhythmias in Cancer Patients Treated with Immune Checkpoint Inhibitors Using Electrocardiogram.

Coskun Alper, Celebi Coskun Ece, Bilgehan Sahin Ahmet, Levent Fatih, Coban Eyup, Koca Fatih, Sali Seda, Demir Omer Furkan, Deligonul Adem, Tenekecioglu Erhan, Cubukcu Erdem, Vatansever Agca Fahriye, Evrensel Turkkan

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Immune checkpoint inhibitor (ICI)-associated cardiovascular adverse events are relatively uncommon; they can be life-threatening, particularly when involving malignant ventricular arrhythmias. Electrocardiographic markers such as P-wave dispersion (PWD), QT dispersion (QTd), T-peak to T-end (Tp-e) interval, and Tp-e/QT and Tp-e/QTc ratios have been linked to an elevated risk of both atrial and ventricular arrhythmias and sudden cardiac death across various cardiac conditions. Monitoring these parameters may aid in identifying the risk of arrhythmogenic events in cancer patients undergoing ICI therapy.

Methods

This retrospective cohort study analyzed 42 patients with cancer who received ICI therapy and had serial 12-lead electrocardiograms (ECGs) performed at baseline and at three-month intervals during the first year of treatment, from May 2022 to November 2023. ECG parameters including PWD, QTd, Tp-e interval, and Tp-e/QT and Tp-e/QTc ratios were measured and compared between baseline and follow-up time points.

Results

The median follow-up duration was 5.3 months (range: 0.5-18.9 months). No statistically significant differences were observed in any of the ECG parameters between baseline and subsequent measurements (p > 0.05). One patient developed atrial fibrillation during the third month of treatment. Additionally, one patient exhibited a left anterior fascicular block, and another experienced frequent ventricular extrasystoles. No malignant ventricular arrhythmias were reported throughout the study period.

Conclusions

This study found no significant changes in electrocardiographic markers associated with arrhythmia risk during ICI treatment. Larger, multicenter, prospective studies with extended follow-up are warranted to further elucidate the cardiovascular safety profile of ICIs.

Для цитирования: Coskun Alper, Celebi Coskun Ece, Bilgehan Sahin Ahmet, Levent Fatih, Coban Eyup, Koca Fatih, Sali Seda, Demir Omer Furkan, Deligonul Adem, Tenekecioglu Erhan, Cubukcu Erdem, Vatansever Agca Fahriye, Evrensel Turkkan. Prediction of Cardiac Arrhythmias in Cancer Patients Treated with Immune Checkpoint Inhibitors Using Electrocardiogram.. Diagnostics (Basel, Switzerland). 2025. DOI: 10.3390/diagnostics15101235.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.