Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
Estimation of organ doses based on patient-specific characteristics undergoing chest-abdomen-pelvis CT examinations of tube current modulation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Jing, Liang Baohui, Ye Zirui, Xu Xie, Qin Tian, Fan Yihan, Sun Qingting
Аннотация
This study aimed to investigate the strength of the correlation between organ doses and four computed tomography (CT) dose metrics, and to explore a method for rapidly estimating organ doses in patients undergoing chest-abdominal-pelvic (CAP) CT examinations. We retrospectively collected DICOM images of 43 patients who underwent CAP CT examinations. These images were imported into Archer-CT for organ segmentation and dose calculation. Then, regarding the six radiosensitive organs (spinal cord, lung, oesophagus, stomach, liver, and bladder) that were included in the study, various radiation dose metrics were calculated based on size-specific dose estimate (SSDE) derived from equivalent water diameters (Dw), i.e. SSDEcentrebased onDwin the centre of the scan range, the SSDEmeanbased on the mean SSDEs of all slices, and the organ-specific SSDEorganfor various organs, as prescribed in American Association of Physicists in Medicine Report 220. Subsequently, correlation analyses were applied to evaluate the relationship between the organ doses and each radiation dose metric and to derive conversion factors for rapid estimation of organ doses. The ranked linear correlations of the four dose metrics with each organ dose were as follows, in descending order: SSDEorgan, SSDEmean, CTDIvol, and SSDEcentre. The strongest and weakest correlations were found between organ dose to liver and SSDELiver(R2= 0.88),and between organ dose to the bladder and SSDEBladder(R2= 0.62) respectively, while theR2of the rest of the organ doses to SSDEorganwas around 0.8. The conversion coefficients for estimating organ doses based on SSDEorganfor the spinal cord, lung, oesophagus, liver, stomach, and bladder were 0.75, 1.24, 0.89, 1.17, 1.18, and 0.83, respectively. Higher correlations were observed between organ doses and SSDEorganfor organs involved in this study during CAP CT examinations. Thus, SSDEorgancan be used to simplify and estimate the individualised organ dose for CAP CT examinations.