MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1742271x241264178

Медицинская библиотека · Ultrasound (Leeds, England) · 2024

Telemedicine ultrasound in intensive care unit: A pilot diagnostic accuracy study.

König Klever Emanuele, Silva Gabriela de Oliveira Laguna, da Silva Mariana Motta Dias, da Rocha Jacqueline Castro, da Silva Márcio Gustavo Santanna, Chagas Maria Eulália Vinadé, de Amorim Jerusa da Rosa, Pires Aristóteles de Almeida, Cunha Birriel Daniella, Constant Hilda Maria Rodrigues Moleda, Moreira Taís de Campos, Cabral Felipe Cezar

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Digital health is an opportune way of facilitating the implementation of point-of-care ultrasound (POCUS) in intensive care units (ICUs) of the Brazilian Unified Health System (SUS) through remote tele-mentored ultrasound (RTMUS). Therefore, this pilot diagnostic accuracy study aims to evaluate the sensitivity and specificity of RTMUS, using POCUS as the gold standard for the diagnosis of pulmonary oedema. As a secondary objective, these metrics will be assessed for pneumonia, chronic obstructive pulmonary disease (COPD), pneumothorax, pulmonary embolism, and cardiac tamponade.

METHODS

The study was conducted in three adult ICUs, monitored by the TeleUTI project, and included 23 patients who underwent POCUS carried out by an ICU medical professional and RTMUS carried out by a tele-intensivist from the institution that proposed the project.

RESULTS

The accuracy in diagnosing pulmonary oedema was 71.43%, COPD 89.96%, and for pneumonia, the results showed an accuracy of 65.22%. Analyses demonstrated that RTMUS has the same capability as POCUS for detecting true positive cases of pulmonary oedema, the same results of true negative cases for COPD, and a limitation in performance for pneumonia.

CONCLUSIONS

For COPD and pulmonary oedema, remote examination can support healthcare teams, suggesting that RTMUS has the potential to be a substitute for POCUS. We emphasise that the results should be interpreted within the context of the study, which is considered small and should be validated on a larger scale to consolidate the conclusions.

Для цитирования: König Klever Emanuele, Silva Gabriela de Oliveira Laguna, da Silva Mariana Motta Dias, da Rocha Jacqueline Castro, da Silva Márcio Gustavo Santanna, Chagas Maria Eulália Vinadé, de Amorim Jerusa da Rosa, Pires Aristóteles de Almeida, Cunha Birriel Daniella, Constant Hilda Maria Rodrigues Moleda, Moreira Taís de Campos, Cabral Felipe Cezar. Telemedicine ultrasound in intensive care unit: A pilot diagnostic accuracy study.. Ultrasound (Leeds, England). 2024. DOI: 10.1177/1742271x241264178.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.