MedElevator Войти в исследования
← Поиск публикаций

DOI 10.31348/2026/29

Медицинская библиотека · Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti · 2026

Comparison of Safety and Efficacy of Two Dispersive Hyaluronate OVDs Used in Cataract Surgery.

Stodůlka Pavel, Jirátková Simona, Klimešová Kateřina, Prachařová Zuzana, Tihelková Eva, Uhlářová Petra, Slovák Martin, Randárová Eva

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare safety and efficacy of ophthalmic viscosurgical devices (OVDs) - OphteisBio 3.0 (Rayner) and Healon Endocoat (J&J Vision) in phacoemulsification cataract removal surgery.

MATERIALS AND

METHODS

In this prospective subject/evaluator-masked post-market randomized study patients undergoing phacoemulsification were assigned to receive one of two hyaluronate-based OVDs - OphteisBio 3.0 and Healon Endocoat. The outcomes were the rate of intraocular pressure (IOP) spikes ≥ 30 mmHg at the 7-day postoperative visit, endothelial cell density changes, the surgeon acceptance rate, IOP change from baseline, rates of inflammation and rates of serious and/or device-related adverse events.

RESULTS

The study included 293 eyes - 146 in the Ophteis group and 147 in the Healon group. No IOP spikes were noted at the 7-day postoperative visit with mean IOP of 14.5 mmHg for Ophteis group and 14.3 mmHg for the Healon group. The mean endothelial cell density loss after the surgery was 9.8% in the Ophteis group and 10.2% in the Healon group with no statistically significant difference between the two OVD groups (p = 0.6292). At the 7-day visit, anterior chamber flare was absent in 98% and 99% of eyes in the Ophteis and Healon group, respectively. 82% of eyes had no anterior chamber cells at 7-day visit in both groups. No adverse events were recorded during surgery and at 7-day follow up. No clinically relevant differences were found between the two OVDs.

CONCLUSION

Ophteis 3.0 and Healon Endocoat have comparable results following phacoemulsification surgery.

Для цитирования: Stodůlka Pavel, Jirátková Simona, Klimešová Kateřina, Prachařová Zuzana, Tihelková Eva, Uhlářová Petra, Slovák Martin, Randárová Eva. Comparison of Safety and Efficacy of Two Dispersive Hyaluronate OVDs Used in Cataract Surgery.. Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti. 2026. DOI: 10.31348/2026/29.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.