MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000001557

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2020

Effect of Scleral Lens Oxygen Permeability on Corneal Physiology.

Dhallu Sandeep K, Huarte Sonia Trave, Bilkhu Paramdeep S, Boychev Nikolay, Wolffsohn James S

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

SIGNIFICANCE: This randomized, masked, crossover clinical study identifies that ≥125 Dk materials should be used for scleral lens daily wear if disruption to corneal oxygen is to be minimized.

PURPOSE: Modern scleral lens use has increased and has proven to be successful where other types and materials have previously failed. Although the required oxygen permeability has been modeled, this has not been established clinically.

METHODS

Fifteen masked participants aged 20.7 ± 2.3 years (10 female) were bilaterally fitted with five different scleral lenses (65, 100, 125, 163, and 180+ Dk) of the same shape profile and one soft silicone hydrogel lens compared with no lens wear on separate occasions in a randomized order. A masked researcher measured corneal thickness and fluid reservoir depth, corneal curvature, objective bulbar and limbal redness, corneal biomechanics, and ocular surface oxygen consumption before and after 8 hours of wear. In addition, comfort scores were obtained using a visual analog scale.

RESULTS

Scleral lenses with oxygen permeability of 65 Dk resulted in greater corneal thickness (1.37 ± 1.25%) after 8 hours of wear versus ≥100 Dk materials (0.58 ± 0.99%; F = 17.215, P < .001) because of stromal thickening; edema with ≥100 Dk materials was associated with fluid reservoir depth (r = 0.231, P = .05). Fluid reservoir depth decreased similarly with all oxygen-permeable lenses from 325.6 ± 99.1 μm to 174.2 ± 100.8 μm after 8 hours of wear (F = 0.961, P = .44). Oxygen consumption reduced with ≤125 Dk lenses (χ = 604.196, P < .001). Soft and scleral lens wear had no effect on corneal curvature, corneal biomechanics, or ocular hyperemia (P > .05). Soft lenses were more comfortable than all the scleral lenses (P < .05), and the 180+ Dk lenses had the best comfort among the sclerals (P < .05).

CONCLUSIONS

A ≥125 Dk is advised for safe scleral lens daily wear. Scleral lens wear leads to an increase in corneal thickness, regardless of lens-material oxygen permeability because of the fluid reservoir depth.

Для цитирования: Dhallu Sandeep K, Huarte Sonia Trave, Bilkhu Paramdeep S, Boychev Nikolay, Wolffsohn James S. Effect of Scleral Lens Oxygen Permeability on Corneal Physiology.. Optometry and vision science : official publication of the American Academy of Optometry. 2020. DOI: 10.1097/opx.0000000000001557.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.