m+Medelevator.RU
← Поиск публикаций
PloS one · 2026

Cornea biomechanics and biometric evaluations in immunoglobulin G4-related ophthalmic disease.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lai Kenneth Ka Hei, Aljufairi Fatema Mohamed Ali Abdulla, Sebastian Jake Uy, Liao Xulin, Chen Wanxue, Hu Zhichao, Wei Yingying, Jia Ruofan, Wah Cheuk, Cheng Andy Chi On, Chin Joyce Kar Yee, Kuk Andrew Kt, Kwong Chi Ho, Yip Nelson Kwok Foo, Lam Wendy, Li Kenneth Kai Wai, Yang Ngai, Yip Wilson Wai Kuen, Young Alvin Lerrmann, Chan Edwin, Ko Callie Ka Li, Chan Carmen Ka Man, Yuen Hunter Kwok Lai, Chen Li Jia, Tham Clement Chee Yung, Pang Chi Pui, Chong Kelvin Kam Lung

Аннотация

PURPOSE: To evaluate the corneal biomechanical and biometric properties in immunoglobulin G4-related ophthalmic disease (IgG4-ROD) patients.

SETTING: Ethnic Han Chinese biopsy-proven IgG4-ROD patients from a territory wide cohort and sex-, age-, smoking- and lens status-matched healthy controls.

DESIGN: A case-controlled (1:1) study.

METHODS: Corvis ST analyzer and IOL Master 700 biometry assessment.

RESULTS: Sixty-seven eyes from 67 patients with IgG4-ROD (41 = males), aged 63.9 ± 13.1 years and 67 right eyes from 67 healthy ethnically Han Chinese controls were recruited. IgG4-ROD eyes were associated with a more negative applanation 2 velocity (-0.30 versus -0.27 m/s, P = 0.0143), and reduced radius of curvature (7.48 versus 7.98 mm, P = 0.0136). There was no difference in intraocular pressure, applanation 1 length, applanation 1 velocity, applanation 2 length, deformation amplitude and peak distance. Corneal astigmatism was greater in IgG4-ROD eyes (-1.2 versus -0.9 D, P = 0.0132), and the deep axis is along 90.2 degree. There is no difference in the steep and flat keratometry, deep axis, lens thickness, cornea thickness, and anterior chamber depth.

CONCLUSIONS: We found multiple corneal changes in biomechanics and fine structures in a cohort of biopsy-proven IgG4-ROD with potential long-term implications in ocular surface functions. A longitudinal follow-up would be useful to identify the clinical implications and observe if these changes improve with treatments.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты