European heart journal. Case reports · 2024
Intra-aortic balloon pump treatment in an adult patient with a Fontan circulation and acute heart failure: a case report.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Langseth Miriam Sjåstad, Nordstrand Njord, Erikssen Gunnar
Аннотация
BACKGROUND: There is limited evidence for the use of an intra-aortic balloon pump (IABP) in adult patients with a total cavopulmonary, or Fontan circulation.
CASE SUMMARY: A patient in his twenties with a Fontan circulation presented with sepsis, pneumonia, and pulmonary oedema. He was born with a hypoplastic left ventricle, atrioventricular septal defect, and hypoplastic aortic arch, and a total cavopulmonary circulation had been established within his first years of life. Standard of care treatment with antibiotics, non-invasive ventilatory support, loop diuretics, and vasopressors was initiated. Due to persistent pulmonary congestion and increasing general fatigue, an IABP was placed via a femoral artery to offload the failing systemic ventricle. Secondary to IABP treatment, mean arterial pressure rose, and vasodilatory nitroprusside could be introduced. Over 4 days of IABP treatment, the patient's general condition and ventricular systolic function improved significantly.
DISCUSSION: This case suggests that IABP treatment was important in the recovery of our patient with a Fontan circulation, pneumonia, and heart failure. We propose that during IABP treatment, an increase in stroke volume and a reduction in ventricular filling pressure is achieved, thereby increasing the transpulmonary pressure gradient that is central to pulmonary blood flow in Fontan patients. More definitive evidence is necessary to confirm our hypotheses.
CASE SUMMARY: A patient in his twenties with a Fontan circulation presented with sepsis, pneumonia, and pulmonary oedema. He was born with a hypoplastic left ventricle, atrioventricular septal defect, and hypoplastic aortic arch, and a total cavopulmonary circulation had been established within his first years of life. Standard of care treatment with antibiotics, non-invasive ventilatory support, loop diuretics, and vasopressors was initiated. Due to persistent pulmonary congestion and increasing general fatigue, an IABP was placed via a femoral artery to offload the failing systemic ventricle. Secondary to IABP treatment, mean arterial pressure rose, and vasodilatory nitroprusside could be introduced. Over 4 days of IABP treatment, the patient's general condition and ventricular systolic function improved significantly.
DISCUSSION: This case suggests that IABP treatment was important in the recovery of our patient with a Fontan circulation, pneumonia, and heart failure. We propose that during IABP treatment, an increase in stroke volume and a reduction in ventricular filling pressure is achieved, thereby increasing the transpulmonary pressure gradient that is central to pulmonary blood flow in Fontan patients. More definitive evidence is necessary to confirm our hypotheses.