MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/alr.23227

Медицинская библиотека · International forum of allergy & rhinology · 2023

Incidence of hypocortisolism with long-term budesonide irrigation for chronic rhinosinusitis.

Silva Bruna R C, Tyler Matthew A, Ma Yifei, Wang Jane, Nayak Jayakar V, Patel Zara M, Hwang Peter H

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Budesonide irrigations (BIs) are commonly used to control inflammation in chronic rhinosinusitis (CRS). In 2016 we reported an analysis of long-term BI with regard to hypothalamic-pituitary-adrenal axis function. We present a follow-up analysis in a larger cohort of patients with longer follow-up.

METHODS

Patients were candidates for stimulated cortisol testing after regularly performing BI for CRS at least daily for ≥6 months. We retrospectively evaluated all patients who received stimulated cortisol testing at our center between 2012 and 2022. We correlated cortisol levels with the use of BI and other forms of corticosteroids.

RESULTS

We analyzed 401 cortisol test results in 285 patients. The mean duration of use was 34 months. Overall, 21.8% of patients were hypocortisolemic (<18 ug/dL) at first test. In patients who used only BI, the rate of hypocortisolemia was 7.5%, whereas in patients who also used concurrent oral and inhaled corticosteroids, the rate was 40% to 50%. Lower cortisol levels were associated with male sex (p < 0.0001) and concomitant use of oral and inhaled steroids (p < 0.0001). Duration of BI use was not significantly associated with lower cortisol levels (p = 0.701), nor was greater dosing frequency (p = 0.289).

CONCLUSION

Prolonged use of BI alone is not likely to cause hypocortisolemia in the majority of patients. However, concomitant use of inhaled and oral steroids and male sex may be associated with hypocortisolemia. Surveillance of cortisol levels may be considered in vulnerable populations who use BI regularly, particularly in patients using other forms of corticosteroids with known systemic absorption.

Для цитирования: Silva Bruna R C, Tyler Matthew A, Ma Yifei, Wang Jane, Nayak Jayakar V, Patel Zara M, Hwang Peter H. Incidence of hypocortisolism with long-term budesonide irrigation for chronic rhinosinusitis.. International forum of allergy & rhinology. 2023. DOI: 10.1002/alr.23227.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.