m+Medelevator.RU
← Поиск публикаций
American journal of industrial medicine · 2005

Process-related risk of beryllium sensitization and disease in a copper-beryllium alloy facility.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schuler Christine R, Kent Michael S, Deubner David C, Berakis Michael T, McCawley Michael, Henneberger Paul K, Rossman Milton D, Kreiss Kathleen

Аннотация

BACKGROUND: Chronic beryllium disease (CBD), which primarily affects the lungs, occurs in sensitized beryllium-exposed individuals. At a copper-beryllium alloy strip and wire finishing facility we performed a cross-sectional survey to examine prevalences of beryllium sensitization and CBD, and relationships between sensitization and CBD and work areas/processes.

METHODS: Current employees (185) were offered beryllium lymphocyte proliferation testing (BeLPT) for sensitization, clinical evaluation for CBD (if sensitized), and questionnaires. We obtained historical airborne beryllium measurements.

RESULTS: Participation was 83%. Prevalences of sensitization and CBD were 7% (10/153) and 4% (6/153), respectively; this included employees with abnormal BeLPTs from two laboratories, four diagnosed with CBD during the survey, and one each diagnosed preceding and following the survey. Potential BeLPT laboratory problems were noted; one laboratory was twice as likely to have reported an abnormal result (P < 0.05, all tests), and five times as likely to have reported a borderline or uninterpretable result (P < 0.05, first blood draw and all tests). CBD risk was highest in rod and wire production (P < 0.05), where air levels were highest.

CONCLUSIONS: Sensitization and CBD were associated with an area in which beryllium air levels exceeded 0.2 microg/m3, and not with areas where this level was rarely exceeded. Employees at this copper-beryllium alloy facility had similar prevalences of sensitization and CBD as workers at facilities with higher beryllium air levels.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты