Retropupillary iris-claw intraocular lens for the surgical correction of aphakia in cases with microspherophakia.
Аннотация
PURPOSE: This study aimed to evaluate the safety and efficacy of retropupillary fixation of an iris-claw intraocular lens (IOL; Verisyse polymethyl methacrylate IOL, Abbott Medical Optics [AMO], Netherlands) for the surgical correction of aphakia in microspherophakic eyes without sufficient capsular support.
DESIGN
This was a prospective, interventional, noncomparative case series.
METHODS
This interventional case series comprised 17 eyes of 9 microspherophakic patients. Retropupillary fixation of the Verisyse iris-claw IOL (AMO) was performed in all cases. The surgical time was measured. Corrected distance visual acuity, astigmatism, intraocular pressure (IOP), tissue reaction, pigment dispersion, and stability of the IOL were studied 1 day, 3 days, 1 week, 2 weeks, 1 month, and 6 months postoperatively.
RESULTS
Eight patients had familial microspherophakia and one patient had Marfan's syndrome. Eighty-two percent of the cases achieved a visual acuity of 0.3 or better. There was no significant postoperative inflammatory reaction. Transient elevation of IOP was recorded in two cases in the 1st week only. One IOL developed disengagement of one of the haptics from the iris and was successfully re-engaged. All the other IOLs were well centered and stable. The mean surgical time was 18.0 ± 4.5 min.
CONCLUSIONS
Retropupillary fixation of an iris-claw IOL is a safe and effective procedure that provides early visual recovery. It is also a time-saving method for correcting aphakia in microspherophakic eyes without sufficient capsular support.