Cardiac photon-counting detector computed tomography in acute ischemic stroke: diagnostic accuracy for detection of left atrial appendage thrombus.
Аннотация
BACKGROUND
In up to one-third of ischemic stroke patients, no cause can be identified. Left atrial appendage (LAA) is the primary anatomical origin of cardiac embolism, yet it is often inadequately assessed in stroke etiological workup.
OBJECTIVES
The goal of this study was to analyze the diagnostic accuracy of cardiac photon-counting detector computed tomography (PCD-CT) integrated in the acute stroke imaging protocol for detection of LAA thrombus.
DESIGN
Retrospective diagnostic accuracy study.
METHODS
We selected consecutive patients with acute ischemic stroke or transient ischemic attack undergoing emergent cardiac PCD-CT and transesophageal echocardiography (TEE) between 2023 and 2025. Cardiac PCD-CT and TEE were assessed for the detection of LAA thrombus. Patients with and without LAA thrombus (defined by PCD-CT) were compared. Diagnostic performance metrics for cardiac PCD-CT for LAA thrombus detection were calculated using TEE as the gold standard.
RESULTS
We included 101 patients, 42 were female (42%), median age was 59 years, 87 patients had acute ischemic stroke (86%). Median time between cardiac PCD-CT and TEE was 2 days. LAA thrombus defined by PCD-CT was present in 12 patients (12%). Patients with LAA thrombus were older (74 vs 58 years, p < 0.001) and more frequently had atrial fibrillation (83.3% vs 23.6%, p < 0.001). Diagnostic accuracy of PCD-CT was 96% (95% confidence interval (95%CI) = 90%-99%), sensitivity was 90% (95%CI = 56-100), specificity was 97% (95%CI = 91%-99%), positive predictive value was 75% (95%CI = 49%-90%), and negative predictive value was 99% (95%CI = 93%-100%).
CONCLUSION
Cardiac PCD-CT integrated as part of the acute stroke imaging protocol is a promising diagnostic tool that may reliably exclude the presence of LAA thrombus.