Quan L, Li S, George C W, Brown B, Yizhi L
Аннотация
OBJECTIVE: To investigates the clinical application value of hyperacuity test for evaluating vision through dense cataracts.
METHODS: Ten normal subjects (20 years) were tested both with Bailey-Lovie type chart and three points vernier acuity test (one of the hyperacuity test); and retinometer test were performed preoperatively and postoperatively in 30 patients (31 eyes) with senile cataract. These patients' lens opacity was classified with LOCS III system.
RESULTS: The correlation of vernier acuity and visual acuity of normal subjects is significant. The result of difference compression of pre-surgical and post-surgical vernier acuity of 30 cataract patients is not significant. The correlation of retinometer findings with post-surgical visual acuity shows not statistically significant. Our result shows that there is good correlation between vernier acuity and post-surgical visual acuity.
CONCLUSION: It appears that hyperacuity is a good test for foveal function behind dense cataract and other ocular opacities.
METHODS: Ten normal subjects (20 years) were tested both with Bailey-Lovie type chart and three points vernier acuity test (one of the hyperacuity test); and retinometer test were performed preoperatively and postoperatively in 30 patients (31 eyes) with senile cataract. These patients' lens opacity was classified with LOCS III system.
RESULTS: The correlation of vernier acuity and visual acuity of normal subjects is significant. The result of difference compression of pre-surgical and post-surgical vernier acuity of 30 cataract patients is not significant. The correlation of retinometer findings with post-surgical visual acuity shows not statistically significant. Our result shows that there is good correlation between vernier acuity and post-surgical visual acuity.