m+Medelevator.RU
← Поиск публикаций
Transactions of the American Ophthalmological Society · 1993

Lack of complications of the hydroxyapatite orbital implant in 250 consecutive cases.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shields C L, Shields J A, De Potter P, Singh A D

Аннотация

The coral-derived hydroxyapatite sphere is a popular, new integrated orbital implant designed to provide improved motility of the ocular prosthesis following enucleation. Although the implant has rapidly become widely used by ophthalmologists, there is little information available regarding the complications of this technique in a large series of cases. We report our results on our initial 250 consecutive cases of hydroxyapatite implantation for eyes enucleated primarily for intraocular neoplasms, with specific emphasis on the complication an their management. The reasons for enucleation included uveal melanoma (157 cases), retinoblastoma (70 cases), blind painful eye (22 cases), and intraocular medulloepithelioma (1 case). Prior treatment to the eye was performed before enucleation in 47 cases and included repair of ruptured globe (17 cases), plaque radiotherapy (18 cases), external beam radiotherapy (6 cases), and others (6 cases). During a mean of 23 months follow-up (range, 6 to 42 months), there have been no recognizable cases of orbital hemorrhage related to the implant and no cases of implant extrusion or implant migration. There was one case of presumed orbital infection (culture-negative) that resolved with intravenous antibiotics, and the implant was retained within the orbit. Other problems included conjunctival thinning in eight cases managed by observation and prosthesis adjustment and conjunctival erosion in four cases managed by combinations of scleral patch graft, conjunctival flap, and prosthesis adjustment. The conjunctival erosion was caused by a poorly fitting prosthesis in three cases and wound dehiscence in one case. The complication rate in eyes receiving prior radiotherapy or surgery was not increased. The hydroxyapatite integrated orbital implant is a well-tolerated motility implant without the high rate of extrusion and infection seen with other motility implants.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты