m+Medelevator.RU
← Поиск публикаций
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2021

Long-term results of thoracoscopic ablation of paroxysmal atrial fibrillation: is the glass half full or half empty?

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Belluschi Igor, Lapenna Elisabetta, Carino Davide, Trumello Cinzia, Cireddu Manuela, Ruggeri Stefania, Schiavi Davide, Monaco Fabrizio, Pozzoli Alberto, Agricola Eustachio, Alfieri Ottavio, De Bonis Michele, Benussi Stefano

Аннотация

OBJECTIVES: Previous series showed the outcomes of thoracoscopic ablation of stand-alone symptomatic paroxysmal atrial fibrillation (AF) for up to 7 years of follow-up. The goal of this study was to assess the long-term durability of surgical pulmonary vein isolation (PVI) beyond 7 years.

METHODS: Fifty consecutive patients {mean age 55 [standard deviation (SD): 11.2] years, previous catheter ablation in 56%, left ventricular ejection fraction 60% (SD: 4.6), left atrium volume 65 ml (SD: 17)} with stand-alone symptomatic paroxysmal AF underwent PVI through bilateral thoracoscopy ablation between 2005 and 2014. The CHA2DS2-VASc score was ≥2 in 12 patients (24%).

RESULTS: No hospital deaths occurred. At hospital discharge all patients but 1 (2%) were in sinus rhythm (SR). Follow-up was 100% complete [mean 8.4 years (SD: 2.3), max 15]. The 8-year cumulative incidence function of AF recurrence, with death as a competing risk, on or off class I/III antiarrhythmic drugs (AADs)/electrocardioversion/re-transcatheter ablation (TCA) was 20% (SD: 5; 95% confidence interval: 10, 32); and off class I/III AADs/electrocardioversion/re-TCA was 52% (SD: 7; 95% confidence interval: 0.83, 8.02). At 8 years, the predicted prevalence of patients in SR was 87% and 53% were off class I/III AADs/electrocardioversion/re-TCA. The recurrent arrhythmia was AF in all patients except 2, who had atypical atrial flutter (4%). No predictors of AF recurrence were identified. At the last follow-up, 76% of the patients showed European Heart Rhythm Association class I. No strokes or thromboembolic events were documented and 76% of the subjects were off anticoagulation therapy.

CONCLUSIONS: Despite a considerable AF recurrence rate, our single-centre, long-term outcome of surgical PVI showed encouraging data, with the majority of patients remaining in SR, although many of them were on antiarrhythmic therapy.