MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.physio.2010.06.004

Медицинская библиотека · Physiotherapy · 2010

Haematological effect of pulsed ultrasound in acute muscular inflammation in rats.

Signori Luis Ulisses, Costa Silvio Teixeira da, Neto Adão Felix Saurin, Pizzolotto Rodrigo Machado, Beck Cristiane, Sbruzzi Graciele, Silva Antônio Marcos Vargas da, Plentz Rodrigo Della Méa

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the effect of low-intensity pulsed ultrasound (LIPUS) on the haematological dynamics of an acute inflammatory process after an iatrogenic muscular lesion.

DESIGN

Controlled laboratory study.

SETTING

Research laboratory.

PARTICIPANTS

Eighteen male Wistar rats (weight 350 to 450g) were submitted to surgical incision in the biceps femoris muscle (approximately 50%), and subsequently subdivided into control (n=9) and LIPUS (n=9) groups.

INTERVENTION: Ultrasound (1.0MHz) was applied at the lesion site in the pulsed mode (2ms on, 8ms off) at 0.4W/cm(2) for 3 minutes at 1, 8 and 24 hours post-surgery.

MAIN OUTCOME MEASURES: In these periods, blood was collected through venepuncture of the retro-orbital plexus and evaluated for different types of leukocytes and erythrocytes.

RESULTS

LIPUS reduced the total leukocyte count at 1, 8 and 24 hours post-surgery (1 hour, control 9017.2±481×10(3)/mm(3) vs LIPUS 6189.8±450×10(3)/mm(3); 8 hours, control 8078.2±501×10(3)/mm(3) vs LIPUS 5371.3±378×10(3)/mm(3); 24 hours, control 8192.3±646×10(3)/mm(3) vs LIPUS 6059.1±503×10(3)/mm(3); P<0.001). The monocyte count was reduced at 8 and 24 hours post-surgery (8 hours, control 815.5±126×10(3)/mm(3) vs LIPUS 375.4±70×10(3)/mm(3); 24 hours, control 875.3±124×10(3)/mm(3) vs LIPUS 564.7±56×10(3)/mm(3); P<0.001). The number of segmented neutrophils was only reduced at 1 hour post-surgery (control 5033.1±397×10(3)/mm(3) vs LIPUS 3594.8±191×10(3)/mm(3); P=0.006), and the lymphocyte count was only reduced at 8 hours post-surgery (control 4759.7±459×10(3)/mm(3) vs LIPUS 2584.1±356×10(3)/mm(3); P=0.003). Changes were not observed in the concentrations of young neutrophils, polibocytes and erythrocytes.

CONCLUSION

LIPUS reduced aspects of the inflammatory process following an acute incisional muscular lesion.

Для цитирования: Signori Luis Ulisses, Costa Silvio Teixeira da, Neto Adão Felix Saurin, Pizzolotto Rodrigo Machado, Beck Cristiane, Sbruzzi Graciele, Silva Antônio Marcos Vargas da, Plentz Rodrigo Della Méa. Haematological effect of pulsed ultrasound in acute muscular inflammation in rats.. Physiotherapy. 2010. DOI: 10.1016/j.physio.2010.06.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.