MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2026.01.313

Медицинская библиотека · JACC. Cardiovascular interventions · 2026

Impact of Leaflet Modification on the Occurrence of Hypoattenuated Leaflet Thickening After Valve-in-Valve Transcatheter Aortic Valve Replacement.

Rotta Detto Loria Johannes, Dumpies Oliver, Abdelhafez Ahmed, Richter Ines, Majunke Nicolas, Feistritzer Hans-Josef, Lankisch Niklas, Gohmann Robin F, Noack Thilo, Desch Steffen, Thiele Holger, Abdel-Wahab Mohamed

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) is an established therapy for failed bioprosthetic valves but carries risks for coronary obstruction and subclinical leaflet thrombosis, characterized by hypoattenuated leaflet thickening (HALT) on multidetector computed tomography. Intentional leaflet modification techniques, such as BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction), have been developed to prevent coronary obstruction, but their impact on leaflet thrombosis remains unclear.

OBJECTIVES

The aim of this study was to evaluate the association of intentional leaflet modification with the incidence of HALT in patients undergoing ViV TAVR.

METHODS

In a retrospective analysis of 141 patients undergoing ViV TAVR with postprocedural multidetector computed tomography, 61 patients received leaflet modification, and 80 underwent standard ViV TAVR without leaflet modification. Baseline characteristics, post-TAVR computed tomographic findings including HALT, and other procedural outcomes were compared. A sensitivity analysis stratified outcome by transcatheter heart valve type. Predictors of HALT were assessed using multivariable logistic regression with clinically relevant covariates.

RESULTS

Leaflet modification was more frequently performed in female patients (62.3% vs 45%; P = 0.04) and those with small (≤21 mm) prosthetic valves (50% vs 22.5%; P < 0.001). Patients undergoing leaflet modification had significantly lower postprocedural mean transvalvular gradients (13 ± 6 mm Hg vs 18 ± 9 mm Hg; P < 0.001) and a reduced incidence of HALT (19.7% vs 40%; P < 0.01) compared with those without leaflet modification. These findings persisted after the analysis was restricted to self-expanding transcatheter heart valves. HALT involving multiple leaflets was numerically less common with leaflet modification (33.3% vs 65.6%; P = 0.054), and thrombosis predominantly affected nonlacerated cusps (66.6% vs 33.3%). No cases of HALT were observed in patients undergoing dual-leaflet modification. Reduced leaflet motion was identified in one-third of patients with HALT, with no significant difference between groups.

CONCLUSIONS

In patients undergoing ViV TAVR, intentional leaflet modification is associated with a significantly reduced incidence of HALT, suggesting a protective association with subclinical leaflet thrombosis. These results support a potentially hemodynamic benefit of leaflet modification beyond coronary obstruction prevention.

Для цитирования: Rotta Detto Loria Johannes, Dumpies Oliver, Abdelhafez Ahmed, Richter Ines, Majunke Nicolas, Feistritzer Hans-Josef, Lankisch Niklas, Gohmann Robin F, Noack Thilo, Desch Steffen, Thiele Holger, Abdel-Wahab Mohamed. Impact of Leaflet Modification on the Occurrence of Hypoattenuated Leaflet Thickening After Valve-in-Valve Transcatheter Aortic Valve Replacement.. JACC. Cardiovascular interventions. 2026. DOI: 10.1016/j.jcin.2026.01.313.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.