Severe Hemoptysis Caused by Right Inferior Pulmonary Vein Perforation During Circular-Array Pulsed-Field Ablation.

Kishaba Junichi, Sagawa Yuichiro, Murata Kazuya, Arai Hirofumi, Oda Atsuhito, Yasui Yumi, Kato Yuki, Arima Hideki, Yamauchi Yasuteru

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Pulsed-field ablation (PFA) has emerged as a novel energy source for pulmonary vein isolation in atrial fibrillation. Although generally safe, rare complications may occur during catheter manipulation in challenging pulmonary veins.

CASE SUMMARY: A 71-year-old man underwent PFA with a circular-array catheter for paroxysmal atrial fibrillation. Echocardiography showed preserved left ventricular systolic function and a left atrial diameter of 39 mm. The right inferior pulmonary vein (RIPV) measured 15 mm at the ostium but bifurcated immediately, complicating catheter advancement. During circular-array catheter manipulation in RIPV, oxygen desaturation occurred, requiring endotracheal intubation. Hemoptysis developed, and bronchoscopy revealed bleeding from the right-lower-lobe bronchus, suggesting RIPV perforation. Idarucizumab and protamine were administered, and contrast-enhanced computed tomography confirmed extravasation. Bleeding resolved with supportive care, and the patient was discharged after 13 days.

DISCUSSION: This case highlights a rare but serious complication associated with challenging RIPV anatomy during PFA.

TAKE-HOME MESSAGE: Careful manipulation of a guidewire and a circular-array catheter is essential in narrow, branching pulmonary vein to prevent vascular injury.

Для цитирования: Kishaba Junichi, Sagawa Yuichiro, Murata Kazuya, Arai Hirofumi, Oda Atsuhito, Yasui Yumi, Kato Yuki, Arima Hideki, Yamauchi Yasuteru. Severe Hemoptysis Caused by Right Inferior Pulmonary Vein Perforation During Circular-Array Pulsed-Field Ablation.. JACC. Case reports. 2026. DOI: 10.1016/j.jaccas.2026.108386.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.