MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1157/13125814

Медицинская библиотека · Anales de pediatria (Barcelona, Spain : 2003) · 2008

[Chronic pulmonary insufficiency after tetralogy of Fallot and pulmonary stenosis intervention. Pulmonary valve replacement with mechanical prosthesis].

Martínez-Quintana E, Rodríguez González F, Agredo Muñoz J, García Mendieta J S, Brito Pérez J M, Llorens León R, Nieto Lago V

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Tetralogy of Fallot and pulmonary stenosis are a frequent cause of consultation in patients with congenital heart disease. Interventions performed in infancy can cause residual pulmonary insufficiency and may require pulmonary valve replacement when adults.

METHODS

From 2003 to 2007, 37 patients underwent right ventricular outflow tract or pulmonary valve intervention (tetralogy of Fallot and pulmonary stenosis). Differences between echocardiographic parameters in both pathologies, indications for pulmonary valvular replacement and the type of prosthesis used, were studied.

RESULTS

25 (67.6 %) patients had tetralogy of Fallot and 12 (32.4 %) pulmonary stenosis. In the pulmonary stenosis group, 7 patients had pulmonary valvulotomy in infancy and 5 had percutaneous pulmonary valvuloplasty in adulthood. Fallot patients received a transannular patch. No significant differences were seen in echocardiographic parameters (right and left ventricular diameter, pulmonary insufficiency, transpulmonary gradient and left ventricular ejection fraction). Mechanical prosthesis valve replacement was performed in 5 (13.5 %) patients, with no morbidity-mortality and with a significant improvement of the functional class.

CONCLUSIONS

Chronic pulmonary insufficiency is a frequent complication after intervention of tetralogy of Fallot and pulmonary stenosis. Mechanical prosthesis valve replacement has low morbidity-mortality and low risk of complications after short to medium-term follow-up.

Для цитирования: Martínez-Quintana E, Rodríguez González F, Agredo Muñoz J, García Mendieta J S, Brito Pérez J M, Llorens León R, Nieto Lago V. [Chronic pulmonary insufficiency after tetralogy of Fallot and pulmonary stenosis intervention. Pulmonary valve replacement with mechanical prosthesis].. Anales de pediatria (Barcelona, Spain : 2003). 2008. DOI: 10.1157/13125814.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление