m+Medelevator.RU
← Поиск публикаций
Clinical chemistry and laboratory medicine · 2025

A novel corrective model based on red blood cells indices and haemolysis index enables accurate unhaemolysed potassium determination in haemolysed samples - Hemokalc project.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lefèvre Charles R, Vigier Bérénice, Favalelli Mathilde, Garnier Jordan, Scanff Alexandre, Pawlowski Maxime, Collet Nicolas, Bendavid Claude

Аннотация

OBJECTIVES: Haemolysis is a major preanalytical issue that affects potassium measurements, often leading to sample rejection and delayed clinical management. This study proposes a novel corrective model for accurate unhaemolysed potassium prediction.

METHODS: Blood samples from 14 healthy volunteers were used to prepare a range of haemolysates via freeze-thaw method. First, the relationship between potassium variation and haemolysis variation (ΔK/ΔHI) was studied both individually and globally to assess inter-individual variability. Then, to achieve a more personalised unhaemolysed potassium prediction, a novel corrective model was developed based on: potassium levels in paired unhaemolysed and gradually haemolysed samples, measured haemolysis index, mean corpuscular haemoglobin concentration, mean corpuscular volume and intraerythrocytic potassium level. The bias between true and model-predicted unhaemolysed potassium values was calculated and compared to the reference change value (RCV%).

RESULTS: Global data showed a strong correlation between ΔK and ΔHI (Pearson r=0.97, p<0.0001), following a linear relationship: ΔK=0.33*ΔHI (p<0.0001). However, individual data revealed substantial inter-individual variation (min ΔK=0.23*ΔHI and max ΔK=0.39*ΔHI). The correction model achieved 100 % accuracy for the 116 prepared samples, with predicted unhaemolysed potassium values falling within a ± 10 % bias range (mean ± standard deviation of bias = -0.5 ± 2.8 %).

CONCLUSIONS: We propose a novel, reliable, and cost-effective corrective model to predict unhaemolysed potassium from haemolysed samples. Compared with previously published models, the integration of red blood cells indices allows for a more personalised, patient-centred approach with high efficiency.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты