m+Medelevator.RU
← Поиск публикаций
Korean journal of ophthalmology : KJO · 2025

Modified Four-Flanged Intrascleral Fixation of Foldable Intraocular Lenses Using a 1-Inch, 30-Gauge Needle for Extraocular Suture Threading.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ha Jun Young, Cho Yong Gu, Yang Yun Sik

Аннотация

PURPOSE: To evaluate the efficacy and safety of modified four-flanged intrascleral fixation of foldable intraocular lenses (IOLs) using a 1-inch 30-gauge needle for extraocular suture threading.

METHODS: This retrospective case series included 20 eyes of 20 patients who underwent four-flanged intrascleral IOL fixation using a 1-inch 30-gauge needle, with at least 6 months of follow-up. We modified the original Canabrava technique by inserting a foldable IOL through a 2.4-mm clear corneal incision with a standard injector and performing extraocular suture threading with a 1-inch 30-gauge needle. Collected data included uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), intraocular pressure, spherical equivalent (SE), prediction error (PE), and corneal and lens astigmatism. Postoperative complications and IOL centration were also evaluated.

RESULTS: Visual acuity improved significantly over the 6-month follow-up; mean preoperative logMAR UCVA was 1.25 ± 0.66 (Snellen equivalent, 20 / 355) and improved to 0.35 ± 0.19 (20 / 45), and logMAR BCVA improved from 0.53 ± 0.38 (20 / 70) to 0.15 ± 0.09 (20 / 30) (p < 0.05). The mean postoperative SE at 6 months was -0.61 ± 1.08 diopters, and PE was -0.25 ± 0.86 diopters. No significant changes in endothelial cell density were observed. Corneal astigmatism remained stable, and lens astigmatism was reduced after surgery, although not significantly. Postoperative complications included one case each of hypotony and vitreous hemorrhage, both resolved with medical therapy. No IOL redislocation, decentration, tilt, or flange-related issues occurred.

CONCLUSIONS: Modified four-flanged intrascleral IOL fixation using a 1-inch 30-gauge needle provides stable IOL fixation by pairing a robust suture with the smallest suitable needle. Extraocular suture threading reduces intraocular manipulation, simplifying the procedure and resulting in favorable visual outcomes and low complication rates.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты