Giordano Arturo, Mas-Peiro Silvia, Fichtlscherer Stephan, Schaefer Andreas, Beyer Martin, Maisano Francesco, Ascione Guido, Buzzatti Nicola, Teles Rui, Brito João, Albuquerque Francisco, Sondergaard Lars, Vanhaverbeke Maarten, Quagliana Angelo, Costa Giuliano, Barbanti Marco, Ferraro Paolo, Morello Alberto, Cimmino Michele, Albanese Michele, Pepe Martino, Bardi Luca, Giordano Salvatore, Cittadini Antonio, Corcione Nicola, Biondi-Zoccai Giuseppe

СтатьяПеревод в очереди

Аннотация

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve.

METHODS

We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed.

RESULTS

A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05).

CONCLUSIONS

Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.

Для цитирования: Giordano Arturo, Mas-Peiro Silvia, Fichtlscherer Stephan, Schaefer Andreas, Beyer Martin, Maisano Francesco, Ascione Guido, Buzzatti Nicola, Teles Rui, Brito João, Albuquerque Francisco, Sondergaard Lars, Vanhaverbeke Maarten, Quagliana Angelo, Costa Giuliano, Barbanti Marco, Ferraro Paolo, Morello Alberto, Cimmino Michele, Albanese Michele, Pepe Martino, Bardi Luca, Giordano Salvatore, Cittadini Antonio, Corcione Nicola, Biondi-Zoccai Giuseppe. Long-term outcomes following transcatheter aortic valve implantation with the Portico self-expanding valve.. Clinical research in cardiology : official journal of the German Cardiac Society. 2023. DOI: 10.1007/s00392-023-02252-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.