An enzyme-linked immunospot assay to evaluate Pneumovax response when on intravenous immunoglobulin.

Izadi Neema, Knight Vijaya, Strand Matthew, Hill Harry R, Peterson Lisa K, Hauk Pia J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Testing for common variable immunodeficiency (CVID) requires evaluation of specific antibody responses to vaccines. Current practice of evaluating pneumococcal serotype-specific immunoglobulin (Ig)G levels after Pneumovax (P23) has several limitations and is not accurate for patients already on immunoglobulin replacement. In contrast, the enzyme-linked immunospot (ELISPOT) assay can be interpreted in patients on immunoglobulin replacement as ex vivo measurement of specific antibody-secreting cells (ASCs).

OBJECTIVE

To optimize and test an ELISPOT assay to evaluate vaccination response to P23 and compare with P23 serotype-specific IgG for patients on intravenous immunoglobulin (IVIG).

METHODS

We prospectively enrolled a total of 15 adults: normal controls (n = 8), patients with CVID on IVIG replacement (n = 2), patients on IVIG replacement for recurrent infections who did not meet diagnostic criteria for CVID, considered IgG deficiency (n = 2), and patients without immunodeficiency on high-dose IVIG for other diagnosis (n = 3). We measured P23 serotype-specific IgG before and 4 weeks after P23 and ELISPOT ASCs before and 1 week after P23 (with B-cell subpopulation analysis by flow cytometry in patients on IVIG).

RESULTS

Normal controls had a vaccination response by P23 serotype-specific IgG, whereas patients on IVIG did not. Except for true patients with CVID on IVIG, a P23 ELISPOT ASC response was found in normal controls (highest) and most patients on IVIG for recurrent infections or other diagnosis.

CONCLUSION

Our pilot study suggests that an optimized ELISPOT protocol has utility to evaluate the P23-specific antibody response after vaccination. Our ELISPOT assay seemed reliable for patients on IVIG and may help differentiate true patients with CVID from those with a less stringent diagnosis while on IVIG.

Для цитирования: Izadi Neema, Knight Vijaya, Strand Matthew, Hill Harry R, Peterson Lisa K, Hauk Pia J. An enzyme-linked immunospot assay to evaluate Pneumovax response when on intravenous immunoglobulin.. Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology. 2021. DOI: 10.1016/j.anai.2021.08.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.