Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2024
Use of 3D Anorectal Ultrasonography in the Preoperative Assessment of Complex Anal Fistulas and Patterns of Healing, Failure, and Recurrence After Ligation of the Intersphincteric Fistula Tract (LIFT).
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Murad-Regadas Sthela M, Regadas Francisco Sergio P, Regadas Filho Francisco Sergio P, Nogueira Felipe R, Holanda Erico de C, Dias Mont'Alverne Ricardo E, da Cunha Carlos Magno Queiroz, Ferreira David G
Аннотация
OBJECTIVES: To use three-dimensional anorectal ultrasonography (3D-US) to evaluate the outcome of ligation of the intersphincteric fistula tract (LIFT) in patients with crypto-glandular transsphincteric fistula and describing the patterns of healing, failure, and recurrence rate.
METHODS: After classifying the fistula and determining the length of the sphincter muscle to be transected, the patients were submitted to LIFT. The accuracy of pre- and postoperative 3D-US with 360° endoprobe (16 MHz) with automatic scanning and clinical findings was evaluated against surgical findings. Three outcomes were considered: healing, failure (persistent anal fistula through the original external opening or intersphincteric), and recurrence (reappearance of the anal fistula).
RESULTS: Sixty-three patients of both sexes were evaluated. The 3D-US assessment revealed primary healing in 50 (79.3%) patients, although in 6 (9.5%) cases healing was delayed and the cavity was without communication with the anal canal. The procedure failed in 9 (15.9%) and fistula recurred in 4 (6.3%), all of whom underwent a second surgery based on a new 3D-US, resulting in a 92.3% (12/13) healing rate on 3D-US.
CONCLUSIONS: A 3D-US was found to be useful in the preoperative assessment of fistulas by quantifying the percentage of muscle to be transected, and in the postoperative assessment by identifying healing, types of failure, and recurrence. The 3D-US was accurate and consistent with surgical findings.
METHODS: After classifying the fistula and determining the length of the sphincter muscle to be transected, the patients were submitted to LIFT. The accuracy of pre- and postoperative 3D-US with 360° endoprobe (16 MHz) with automatic scanning and clinical findings was evaluated against surgical findings. Three outcomes were considered: healing, failure (persistent anal fistula through the original external opening or intersphincteric), and recurrence (reappearance of the anal fistula).
RESULTS: Sixty-three patients of both sexes were evaluated. The 3D-US assessment revealed primary healing in 50 (79.3%) patients, although in 6 (9.5%) cases healing was delayed and the cavity was without communication with the anal canal. The procedure failed in 9 (15.9%) and fistula recurred in 4 (6.3%), all of whom underwent a second surgery based on a new 3D-US, resulting in a 92.3% (12/13) healing rate on 3D-US.
CONCLUSIONS: A 3D-US was found to be useful in the preoperative assessment of fistulas by quantifying the percentage of muscle to be transected, and in the postoperative assessment by identifying healing, types of failure, and recurrence. The 3D-US was accurate and consistent with surgical findings.