MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000048339

Медицинская библиотека · Medicine · 2026

Effect of a modified soft contact lens combined with a noncontact wide-angle viewing system during vitrectomy.

Xia Jintao, Zhang Hongbing, Cheng Lina, Yang Xiaogang

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

To evaluate the efficacy of a modified soft contact lens (MSCL) in maintaining intraoperative visual clarity and protecting the cornea during vitrectomy using a noncontact wide-angle viewing system.

METHODS

Patients undergoing pars plana vitrectomy were randomly assigned to a balanced salt solution (BSS) group or an MSCL group. All surgeries were performed with a noncontact wide-angle viewing system. In the BSS group, the cornea was intermittently irrigated with BSS, whereas an MSCL was applied throughout surgery in the MSCL group. Surgical time, vitrectomy duration, intraoperative visual clarity, and frequency of corneal irrigation were recorded. Corneal epithelial edema, fluorescein staining, tear film breakup time, and central corneal thickness were assessed preoperatively and at 1 day, 1 week, and 1 month postoperatively. Ocular Surface Disease Index scores were evaluated preoperatively and at 1 month.

RESULTS

The MSCL group showed significantly better intraoperative visual clarity and corneal hydration than the BSS group (P < .05). Surgical time and vitrectomy duration were comparable between groups (P > .05). Corneal edema, fluorescein staining, and tear film breakup time at 1 day and 1 week were significantly improved in the MSCL group (P < .05), with no differences at 1 month. Ocular Surface Disease Index scores did not differ significantly between groups.

CONCLUSION

MSCL use effectively protects the cornea and improves intraoperative visualization during vitrectomy without adversely affecting postoperative ocular surface comfort.

Для цитирования: Xia Jintao, Zhang Hongbing, Cheng Lina, Yang Xiaogang. Effect of a modified soft contact lens combined with a noncontact wide-angle viewing system during vitrectomy.. Medicine. 2026. DOI: 10.1097/md.0000000000048339.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.