Artificial Intelligence-guided Extra-pulmonary Vein Repeat Ablation with the Pentaspline Pulsed Field Ablation Catheter.

Nair Devi G, Gabrah Kirollos, Nair Ganesh, Doty Brandon, Mahtani Arun

СтатьяПеревод в очереди

Аннотация

The safety and efficacy of pulsed field ablation (PFA) for cardiac ablation have been demonstrated in pulmonary vein (PV) isolation (PVI), but its relevance to target additional extra-PV substrate is still under investigation. We conducted a pilot, prospective, single-center, nonrandomized study in 25 patients with atrial fibrillation despite previous catheter ablation (52% men; 74 ± 9 years of age). Patients underwent catheter ablation using PFA with the goal of ablating artificial intelligence (AI)-guided spatiotemporal dispersion. Biatrial mapping of spatiotemporal dispersion was obtained using the Volta AF-Xplorer™ (Volta Medical, Providence, RI, USA). Re-conducting PVs and extra-PV regions of interest exhibiting dispersion were ablated using the Farawave™ catheter (Boston Scientific, Marlborough, MA, USA). This catheter was used either in the basket or flower configuration sequentially centered at an estimated geometric center of AI-detected dispersion regions. The mean procedure and biatrial mapping times were 75 ± 12 and 14 ± 7 min, respectively, and no fluoroscopy was used. No complications occurred, and sinus rhythm conversion by ablation was obtained in 23 patients (92%). The rate of freedom from any atrial arrhythmia at 6 months was 88%. In conclusion, we observed that PFA for personalized, AI-guided extra-PV dispersion repeat ablation appears safe and procedurally efficient.

Для цитирования: Nair Devi G, Gabrah Kirollos, Nair Ganesh, Doty Brandon, Mahtani Arun. Artificial Intelligence-guided Extra-pulmonary Vein Repeat Ablation with the Pentaspline Pulsed Field Ablation Catheter.. The Journal of innovations in cardiac rhythm management. 2026. DOI: 10.19102/icrm.2026.17045.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.